View larger
IZMX-CT-NGS 156661 EATON ELECTRIC Core-balance transformer
IZMX-CT-NGS
156661
EATON - MOELLER
1 Pcs.
Automation > Current transformer
Circuit Breakers IZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller IZMX-CT-NGS is a core-balance transformer utilized in electrical installations to detect residual and earth leakage currents by summing the vector currents of the conductors passing through its core. Such devices are vital for triggering protective relays to prevent ground faults and ensure personnel safety in industrial switchgear.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Calibrated (EF008836): No
- With contact protection (EF008186): No
- Snap mounting (EF007462): No
- With copper rail (EF007380): No
More info
▲Product range | Accessories | ||
Accessories | Core-balance transformer | ||
| The core-balance transformer can be used for the earth-fault protection or earth-fault alarm function a) for total current measurements in IZMX16 units or b) for directly measuring the ground fault current at the grounded neutral point. Donotplace a jumper in the wiring (between the transformer and the circuit-breaker's terminals) between: 17, 18 and 19, 20 for a) and b). | |||
For use with | IZMX-DTV-G +IZMX-DTV-G +IZMX-DTV-GZ +IZMX-DTU-A IZMX-DTU-A +IZMX-DTU-AZ +IZMX-DTU-G IZMX-DTU-G +IZMX-DTU-AM IZMX-DTU-AM +IZMX-DTU-AMZ IZMX-DTU-GMZ IZMX-DTU-GM +IZMX-DTU-GM +IZMX-DTU-GZ IZMX-DTP-G IZMX-DTP-G +IZMX-DTP-GZ +IZMX-DTP-GM +IZMX-DTP-GMZ IZMX-DTP-GM |
Technical data for design verification | |||
Operating ambient temperature min. | °C | -25 | |
Operating ambient temperature max. | °C | 70 |
| Low-voltage industrial components (EG000017) / Current transformer (EC002048) | |||
| Electric engineering, automation, process control engineering / Signal processing / Transformer / Current transformer ([email protected] [AAB626011]) | |||
Model | Wound primary current converter | ||
Primary rated current | A | 4000 | |
Secondary rated current | A | 0 | |
Secondary rated apparent power | VA | 0 | |
Accuracy class | 1 | ||
Over voltage limiting factor | - | ||
Calibrated | No | ||
With shock protection | No | ||
Opening height | mm | 0 | |
Opening width | mm | 0 | |
Opening diameter | mm | 0 | |
Snap mounting | No | ||
With copper rail | No | ||
Secondary connection | Screw connection | ||
Number of primary inputs | 1 | ||