View larger
EASY806-DC-SWD 152902 EATON ELECTRIC Control relay, 24 V DC, 4DI(2DI, 2DO), easyNet, SmartWire-DT
EASY806-DC-SWD
152902
EATON - MOELLER
1 Pcs.
Automation > Logic module
EASY programmable relays and MFD displays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller control relay, part number EASY806-DC-SWD, integrates advanced communication capabilities such as SmartWire-DT connectivity for streamlined device networking in machine building. Such programmable controllers manage distributed automation nodes and local sensor networks within automated production lines.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Supply voltage AC 50 Hz (EF007532): 0 V
- Supply voltage AC 60 Hz (EF007533): 0 V
- Supply voltage DC (EF007534): 20.4 V
- Voltage type (supply voltage) (EF002991): DC
- Switching current (EF000188): 0.1 A
- Power consumption (EF000346): 6 W
- Number of analogue inputs (EF001994): 0
- Number of analogue outputs (EF001995): 0
- Number of digital inputs (EF001992): 4
- Number of digital outputs (EF001993): 2
- With relay output (EF003198): No
- Number of HW-interfaces industrial Ethernet (EF003020): 0
- Number of interfaces PROFINET (EF006932): 0
- Number of HW-interfaces RS-232 (EF003021): 0
- Number of HW-interfaces RS-422 (EF003022): 0
- Number of HW-interfaces RS-485 (EF003023): 0
More info
▲Delivery program
Up to 99 SmartWire-DT modules with a total of up to 166 digital inputs/outputs and/or up to 128 analog inputs/outputs can be connected via a SmartWire-DT line
Networkable (easyNet)
Depending on the hardware, such as integrated analog input/output not supported
Count functions: 2 x incremental value counter up/down (per 2 inputs); 4 x high-speed counter single-channel (per 1 input);
4 x frequency counters (per 1 input)
2 x pulse-width modulated outputs (2 counter inputs omitted)
Technical data
UL
EAC
-40 - +70 °C
5 - 95 %
constant amplitude 0.15 mm: 10 - 57
constant acceleration 2 g: 57 - 150 Hz
1.4 - 2 GHz: 3
2.0 - 2.7 GHz: 1 V/m
Supply cables: 2
Signal cables: 2
easyNet: 2
SWD lines: 2 kV
1 kV (supply cables, symmetrical)
② Service life (years)
≤ 10 ms
between digital inputs: no
from the outputs: no
to COM interface: yes
to easyNet: yes
to AUX: yes
to SmartWire-DT: no
Signal 1: ≧ 15 (I1 - I4) V DC
normally 0.025 (0 -> 1/1 -> 0, Debounce OFF) ms
From the inputs: yes: no
to COM interface: yes
to easyNet: yes
to AUX: yes
U = Ue- 2 V (signal 1 at Ie= 0.1 A) V
depending on number of active channels and their load A
10 A/20 ms (on attempted restart of device after 10s) A
2 (UL) A
From the inputs: yes
from the outputs: yes
to COM interface: yes
to easyNet: yes
to SmartWire-DT: yes
From the inputs: yes: no
from the outputs: no
to COM interface: yes
to easyNet: yes
to AUX: yes
Config. LED: green/red
SmartWire-DT line end with SWD4-RC8-10
500 KBit/s, 25 m
250 Kbit/s, 40 m
125 Kbit/s, 300 m
50 KBit/s, 300 m
20 KBit/s, 700 m
10 KBit/s, 1000 m
Lengths from 40 m can be obtained only with cables with reinforced cross-section and terminal adapter.
From the inputs: yes
from the outputs: yes
to COM interface: yes
to SmartWire-DT: yes
to AUX: yes
up to 600 m, < 26 mΩ/m: 0.75 - 0.8 (AWG: 18)
up to 600 m, < 26 mΩ/m: 0.5 - 0.6 (AWG: 20, 19)
up to 400 m, < 40 mΩ/m: 0.34 - 0.5 (AWG: 22, 21, 20)
up to 250 m, < 60 mΩ/m: 0.25 - 0.34 (AWG: 23, 22)
up to 175 m, < 70 mΩ/m: 0.13 (AWG: 26)
up to 40 m, < 140 mΩ/m: 1.5 (AWG: 16)