View larger
DILAC-40(230V50/60HZ) 276449 XTREC10B40G2 EATON ELECTRIC 276449 DILAC-40(230V50/60HZ)
DILAC-40(230V50/60HZ)
276449
XTREC10B40G2
EATON - MOELLER
1 Pcs.
Automation > Contactor relay
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A control relay is an electromechanical switching device utilized in industrial control circuits to multiply contacts, isolate low-power signals, and sequence automation operations. This unit from Eaton Moeller, part number DILAC-40(230V50/60HZ), ensures reliable signal routing within complex machinery panels.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 230 V
- Rated control supply voltage AC 60 Hz (EF003979): 230 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Rated operation current (EF007679): 16 A
- Rated operation current Ie, 400 V (EF001378): 4 A
- Mounting method (EF000003): DIN-rail/screw
- With LED indication (EF005950): false
- Suitable for manual operation (EF002978): false
- Interface (EF000594): false
- Operating voltage AC 50 Hz (EF008206): 17 V
- Operating voltage AC 60 Hz (EF008207): 17 V
- Operating voltage DC (EF008208): 24 V
- Voltage type (operating voltage) (EF005294): AC/DC
- Rated switch current (EF006706): 16 A
- Connection type auxiliary circuit (EF006820): Spring clamp connection
More info
▲General specifications
IEC 60947-4-1
UL 508
EN 60947-4-1
VDE
UL Category Control No.: NKCR
EN 60947-5-1
CSA
IEC/EN 60947
UL File No.: E29184
CE
CSA File No.: 012528
IEC/EN 60947-4-1
VDE 0660
CSA-C22.2 No. 14-05
UL
CSA Class No.: 3211-03
Features & Functions
General
7 g, N/O auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Climatic environmental conditions
Damp heat, cyclic, to IEC 60068-2-30
Terminal capacities
1 x (0.75 - 1.5) mm², Spring-loaded terminals with or without ferrule DIN 46228
1 x (0.75 - 2.5) mm², Spring-loaded terminals
Electrical rating
2 A at 110 V, DC L/R ≤ 50 ms (with 3 contacts in series)
1 A at 220 V, DC L/R ≤ 15 ms (with 1 contact in series)
4 A at 60 V, DC L/R ≤ 50 ms (with 3 contacts in series)
6 A at 60 V, DC L/R ≤ 15 ms (with 1 contact in series)
6 A at 110 V, DC L/R ≤ 15 ms (with 3 contacts in series)
5 A at 220 V, DC L/R ≤ 15 ms (with 3 contacts in series)
3 A at 110 V, DC L/R ≤ 15 ms (with 1 contact in series)
4 A at 24 V, DC L/R ≤ 50 ms (with 3 contacts in series)
10 A at 24 V, DC L/R ≤ 15 ms (with 1 contact in series)
1 A at 220 V, DC L/R ≤ 50 ms (with 3 contacts in series)
16 A
400 V AC, Between coil and auxiliary contacts, According to EN 61140
1 A, 250 V DC, (UL/CSA)
P300, DC operated (UL/CSA)
Magnet system
27 VA, AC, Dual-frequency coil at 60 Hz