View larger
DILAC-40(24V50/60HZ) 276445 XTREC10B40T EATON ELECTRIC 276445 DILAC-40(24V50/60HZ)
DILAC-40(24V50/60HZ)
276445
XTREC10B40T
EATON - MOELLER
1 Pcs.
Automation > Contactor relay
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller DILAC-40(24V50/60HZ) contactor relay is engineered for dependable control circuit isolation, signal multiplication, and logic routing within automated manufacturing environments. Industrial relays manage auxiliary automation signals without bearing primary heavy loads.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz: 24 V
- Rated control supply voltage AC 60 Hz: 24 V
- Rated control supply voltage DC: 0 V
- Voltage type for actuating: AC
- Rated operation current: 16 A
- Rated operation current Ie, 400 V: 4 A
- Mounting method: DIN-rail/screw
- With LED indication: No
- Suitable for manual operation: No
- Interface: No
- Operating voltage AC 50 Hz: 17 V
- Operating voltage AC 60 Hz: 17 V
- Operating voltage DC: 24 V
- Voltage type (operating voltage): AC/DC
- Rated switch current: 16 A
- Connection type auxiliary circuit: Spring clamp connection
More info
▲General specifications
IEC 60947-4-1
UL 508
EN 60947-4-1
VDE
VDE 0660
CSA File No.: 012528
CSA-C22.2 No. 14-05
IEC/EN 60947
UL File No.: E29184
CSA
UL
CE
EN 60947-5-1
IEC/EN 60947-4-1
UL Category Control No.: NKCR
CSA Class No.: 3211-03
Features & Functions
General
5 g, N/C auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
2 x (0.75 - 1.5) mm², Spring-loaded terminals with or without ferrule DIN 46228
1 x (0.75 - 2.5) mm², Spring-loaded terminals
Electrical rating
5 A at 220 V, DC L/R ≤ 15 ms (with 3 contacts in series)
4 A at 24 V, DC L/R ≤ 50 ms (with 3 contacts in series)
1 A at 220 V, DC L/R ≤ 50 ms (with 3 contacts in series)
4 A at 60 V, DC L/R ≤ 50 ms (with 3 contacts in series)
2 A at 110 V, DC L/R ≤ 50 ms (with 3 contacts in series)
10 A at 24 V, DC L/R ≤ 15 ms (with 1 contact in series)
6 A at 60 V, DC L/R ≤ 15 ms (with 1 contact in series)
10 A at 60 V, DC L/R ≤ 15 ms (with 2 contacts in series)
6 A at 110 V, DC L/R ≤ 15 ms (with 3 contacts in series)
1 A at 220 V, DC L/R ≤ 15 ms (with 1 contact in series)
16 A
400 V AC, Between auxiliary contacts, According to EN 61140
1 A, 250 V DC, (UL/CSA)
A600, AC operated (UL/CSA)
Magnet system
27 VA, AC, Dual-frequency coil at 60 Hz