View larger
DILA-40(230V50/60HZ) 276337 Y7-276337 EATON ELECTRIC 276337 DILA-40(230V50/60HZ)
DILA-40(230V50/60HZ)
276337
Y7-276337
EATON - MOELLER
1 Pcs.
Automation > Contactor relay
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller DILA-40(230V50/60HZ) contactor relay delivers dependable multi-frequency AC auxiliary switching for industrial control assemblies. These components allow automation engineers to coordinate complex electrical interlocks, duplicate control signals, and manage auxiliary circuits. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Manufacturer: Eaton Moeller
- Manufacturer part number: DILA-40(230V50/60HZ)
- Catalogue code: 276337
- Catalogue title: DILA-40(230V50/60HZ) 276337 Y7-276337 EATON ELECTRIC 276337 DILA-40(230V50/60HZ)
- Product description: General specifications Product Name Eaton Moeller® series DILA Control relay Catalog Number 276337 Model Code DILA-40(230V50/60HZ) EAN 4015082763374 Product Length/Depth 75 mm Product Height 68 mm Product Width 45 mm Pro
More info
▲General specifications
UL 508
EN 60947-4-1
CSA Std. C22.2 No. 14-05
VDE
CSA
UL Category Control No.: NKCR
VDE 0660
IEC/EN 60947-4-1
UL File No.: E29184
IEC/EN 60947
CSA-C22.2 No. 14-05
CSA File No.: 012528
CE
CSA Class No.: 3211-03
EN 60947-5-1
UL
Features & Functions
General
5 g, N/C auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Climatic environmental conditions
Damp heat, cyclic, to IEC 60068-2-30
Terminal capacities
1 x (0.75 - 2.5) mm², Screw terminals
2 x (0.75 - 2.5) mm², Screw terminals
0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver
Electrical rating
4 A at 60 V, DC L/R ≤ 50 ms (with 3 contacts in series)
10 A at 60 V, DC L/R ≤ 15 ms (with 2 contacts in series)
5 A at 220 V, DC L/R ≤ 15 ms (with 3 contacts in series)
1 A at 220 V, DC L/R ≤ 50 ms (with 3 contacts in series)
3 A at 110 V, DC L/R ≤ 15 ms (with 1 contact in series)
6 A at 110 V, DC L/R ≤ 15 ms (with 3 contacts in series)
1 A at 220 V, DC L/R ≤ 15 ms (with 1 contact in series)
10 A at 24 V, DC L/R ≤ 15 ms (with 1 contact in series)
4 A at 24 V, DC L/R ≤ 50 ms (with 3 contacts in series)
2 A at 110 V, DC L/R ≤ 50 ms (with 3 contacts in series)
16 A
400 V AC, Between coil and auxiliary contacts, According to EN 61140
15 A, 600 V AC, (UL/CSA)
P300, DC operated (UL/CSA)
Magnet system
27 VA, AC, Dual-frequency coil at 60 Hz