View larger
DILA-40(415V50HZ,480V60HZ) 276332 Y7-276332 EATON ELECTRIC Contactor relay, 4N/O, AC
DILA-40(415V50HZ,480V60HZ)
276332
Y7-276332
EATON - MOELLER
1 Pcs.
Automation > Contactor relay
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller DILA-40(415V50HZ,480V60HZ) contactor relay handles high-voltage auxiliary switching operations across industrial AC environments. Facilities rely on such relays to sequence complex machinery, maintain electrical safety interlocks, and expand control circuit logic. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Manufacturer: Eaton Moeller
- Manufacturer part number: DILA-40(415V50HZ,480V60HZ)
- Catalogue code: 276332
- Catalogue title: DILA-40(415V50HZ,480V60HZ) 276332 Y7-276332 EATON ELECTRIC Contactor relay, 4N/O, AC
- Product description: General specifications Product Name Eaton Moeller® series DILA Control relay Catalog Number 276332 Model Code DILA-40(415V50HZ,48V60HZ) EAN 4015082763329 Product Length/Depth 75 mm Product Height 68 mm Product Width 45
More info
▲General specifications
UL 508
VDE 0660
CSA-C22.2 No. 14-05
IEC/EN 60947
CE
CSA File No.: 012528
UL File No.: E29184
EN 60947-5-1
UL
UL Category Control No.: NKCR
CSA Class No.: 3211-03
IEC/EN 60947-4-1
Features & Functions
General
7 g, N/O auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
2 x (0.75 - 2.5) mm², Screw terminals
1 x (0.75 - 4) mm², Screw terminals
0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver
Electrical rating
10 A at 24 V, DC L/R ≤ 15 ms (with 1 contact in series)
4 A at 24 V, DC L/R ≤ 50 ms (with 3 contacts in series)
4 A at 60 V, DC L/R ≤ 50 ms (with 3 contacts in series)
10 A at 60 V, DC L/R ≤ 15 ms (with 2 contacts in series)
6 A at 60 V, DC L/R ≤ 15 ms (with 1 contact in series)
2 A at 110 V, DC L/R ≤ 50 ms (with 3 contacts in series)
5 A at 220 V, DC L/R ≤ 15 ms (with 3 contacts in series)
6 A at 110 V, DC L/R ≤ 15 ms (with 3 contacts in series)
1 A at 220 V, DC L/R ≤ 15 ms (with 1 contact in series)
3 A at 110 V, DC L/R ≤ 15 ms (with 1 contact in series)
16 A
400 V AC, Between auxiliary contacts, According to EN 61140
15 A, 600 V AC, (UL/CSA)
P300, DC operated (UL/CSA)