DILMP80(230V50/60HZ) 109883 Y7-109883 EATON ELECTRIC 109883 DILMP80(230V50/60HZ)
DILMP80(230V50/60HZ)
109883
Y7-109883
EATON - MOELLER
1 Pcs.
Automation > Power contactor, AC switching
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller DILMP80(230V50/60HZ) is a four-pole contactor tailored for switching specialized industrial loads, including lighting arrays and distribution circuits. Multi-pole contactors ensure uniform circuit breaks across all phases in heavy-duty commercial and manufacturing applications. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 230 V
- Rated control supply voltage AC 60 Hz (EF003979): 230 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Number of normally open contacts as main contact (EF001374): 4
- Type of electrical connection of main circuit (EF006819): Screw connection
- Operating voltage AC 50 Hz (EF008206): 230 V
- Operating voltage AC 60 Hz (EF008207): 230 V
- Rated operation current Ie at AC-1, 400 V (EF001393): 80 A
- Rated operation current Ie at AC-3, 400 V (EF001392): 50 A
- Rated operation power at AC-3, 400 V (EF001364): 22 kW
- Rated operation current Ie at AC-4, 400 V (EF008495): 40 A
- Rated operation power at AC-4, 400 V (EF008496): 20 kW
- Rated operation power NEMA (EF011960): 29.8 kW
- Modular version (EF001126): No
- Width (EF000008): 74 mm
More info
▲General specifications
CSA Class No.: 2411-03, 3211-04
UL File No.: E29096
UL
VDE 0660
UL Category Control No.: NLDX
IEC/EN 60947
CSA File No.: 012528
CSA-C22.2 No. 60947-4-1-14
UL 60947-4-1
IEC/EN 60947-4-1
CSA
Features & Functions
General
10,000,000 Operations (DC operated)
5000 mechanical Operations/h (AC operated)
AC-3: Normal AC induction motors: starting, switch off during running
Ambient conditions, mechanical
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-3
Terminal capacities
2 x (0.75 - 1.5) mm²
2 x (0.75 - 2.5) mm²
1 x (0.75 - 4) mm², Control circuit cables
2 x (2.5 - 16) mm², Main cables
1 x (2.5 - 16) mm², Main cables
1 x (0.75 - 2.5) mm²
18 - 14, Control circuit cables
1 x (16 - 50) mm², Main cables
M6, Terminal screw, Main cables
2, Terminal screw, Pozidriv screwdriver
1.2 Nm, Screw terminals, Control circuit cables
Electrical Rating
Short-circuit rating
10 kA, SCCR (UL/CSA)
250 A, max. CB, SCCR (UL/CSA)
100 A, max. CB, SCCR (UL/CSA)
250/150 A, Class J, max. Fuse, SCCR (UL/CSA)
65 kA, CB, SCCR (UL/CSA)
30 kA, CB, SCCR (UL/CSA)
250/150 A, Class J, max. Fuse, SCCR (UL/CSA)
250 A, max. CB, SCCR (UL/CSA)
Conventional thermal current
Switching capacity
Switching time
Magnet system
0.8 - 1.1 V AC x Uc
150 VA, Dual-frequency coil in a cold state and 1.0 x Us
4.1 W, Dual-frequency coil in a cold state and 1.0 x Us
Motor Rating
Communication
Contacts
Safety
440 V AC, Between coil and contacts, According to EN 61140
Special purpose ratings
79 A (480V 60Hz 3phase, 277V 60Hz 1phase)
40 A, 480 V 60 Hz 3-ph, (UL/CSA)
42 A, 240 V 60 Hz 3-ph, (UL/CSA)
32.2 A, 200 V 60 Hz 3-ph, (UL/CSA)
40 HP, 600 V 60 Hz 3-ph, (UL/CSA)
15 HP, 240 V 60 Hz 3-ph, (UL/CSA)
30 HP, 480 V 60 Hz 3-ph, (UL/CSA)
41 A, 600 V 60 Hz 3-ph, (UL/CSA)
79 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
74 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)