View larger
DILM185A/22(RAC120) 139536 Y7-139536 EATON ELECTRIC Contactor, 3p+2N/O+2N/C, 90kW/400V/AC3
DILM185A/22(RAC120)
139536
Y7-139536
EATON - MOELLER
1 Pcs.
Automation > Power contactor, AC switching
Contactors more than 170 A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller DILM185A/22(RAC120) Contactor is a heavy-duty industrial switching device designed for high-capacity motor control and heavy power distribution networks. These units ensure robust and dependable electrical isolation in large manufacturing facilities.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 100 V
- Rated control supply voltage AC 60 Hz (EF003979): 100 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Number of normally open contacts as main contact (EF001374): 3
- Type of electrical connection of main circuit (EF006819): Rail connection
- Operating voltage AC 50 Hz (EF008206): 100 V
- Operating voltage AC 60 Hz (EF008207): 100 V
- Rated operation current Ie at AC-1, 400 V (EF001393): 337 A
- Rated operation current Ie at AC-3, 400 V (EF001392): 185 A
- Rated operation power at AC-3, 400 V (EF001364): 90 kW
- Rated operation current Ie at AC-4, 400 V (EF008495): 136 A
- Rated operation power at AC-4, 400 V (EF008496): 75 kW
- Rated operation power NEMA (EF011960): 93 kW
- Modular version (EF001126): No
- Width (EF000008): 140 mm
More info
▲General specifications
IEC 60947-4-1
UL 508
CSA Std. C22.2 No. 14-05
VDE
CE
IEC/EN 60947-4-1
CSA Class No.: 3211-04
UL Category Control No.: NLDX
UL File No.: E29096
UL
CSA
IEC/EN 60947
CSA-C22.2 No. 60947-4-1-14
UL 60947-4-1
CSA File No.: 2389068
VDE 0660
Global
3000 mechanical Operations/h (AC operated)
8 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
AC-3: Normal AC induction motors: starting, switch off during running
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
General
Damp heat, constant, to IEC 60068-2-78
3000 mechanical Operations/h (AC operated)
8 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
AC-3: Normal AC induction motors: starting, switch off during running
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
Climatic environmental conditions
2 x (0.75 - 2.5) mm², Control circuit cables
1 x (0.75 - 2.5) mm², Control circuit cables
18 - 14, Control circuit cables
M3.5, Terminal screw, Control circuit cables
1.2 Nm, Screw terminals, Control circuit cables
Terminal capacities
220 A at up to 525 V (Individual compensation, three-phase capacitors, open)
336 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
1680 A, LRA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
280 A, FLA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Electrical rating
700 A, max. Fuse, SCCR (UL/CSA)
10 kA, SCCR (UL/CSA)
600 A, Class J, max. Fuse, SCCR (UL/CSA)
350 A, max. CB, SCCR (UL/CSA)
65 kA, CB, SCCR (UL/CSA)
100 kA, Fuse, SCCR (UL/CSA)
600 A, Class J, max. Fuse, SCCR (UL/CSA)
50 kA, CB, SCCR (UL/CSA)
220 A at up to 525 V (Individual compensation, three-phase capacitors, open)
336 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
1680 A, LRA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
280 A, FLA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Short-circuit rating
Conventional thermal current Ith
1 A, 250 V DC, (UL/CSA)
A600, AC operated (UL/CSA)
Switching capacity
AC operated: 0.2 x US max - 0.4 x US min, AC operated
210 VA, Pull-in power, Coil in a cold state and 1.0 x Us
210 VA, Pull-in power, Coil in a cold state and 1.0 x Us
2.6 VA, Coil in a cold state and 1.0 x Us
2.6 VA, Coil in a cold state and 1.0 x Us
Magnet system
210 VA, Pull-in power, Coil in a cold state and 1.0 x Us
210 VA, Pull-in power, Coil in a cold state and 1.0 x Us
2.6 VA, Coil in a cold state and 1.0 x Us
2.6 VA, Coil in a cold state and 1.0 x Us