DILM500-S/22(220-240V50/60HZ) 274199 Y7-274199 EATON ELECTRIC Contactor, 3p+2N/O+2N/C, 250kW/400V/AC3
DILM500-S/22(220-240V50/60HZ)
274199
Y7-274199
EATON - MOELLER
1 Pcs.
Automation > Power contactor, AC switching
Contactors more than 170 A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller DILM500-S/22(220-240V50/60HZ) 274199 Y7-274199 EATON ELECTRIC Contactor, 3p+2N/O+2N/C, 250kW/400V/AC3 is a heavy-duty industrial contactor designed for managing high-power electric motors and heavy electrical loads safely. It provides robust electrical switching capacity for large commercial and industrial installations.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 220 V
- Rated control supply voltage AC 60 Hz (EF003979): 220 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Number of normally open contacts as main contact (EF001374): 3
- Type of electrical connection of main circuit (EF006819): Rail connection
- Operating voltage AC 50 Hz (EF008206): 220 V
- Operating voltage AC 60 Hz (EF008207): 220 V
- Rated operation current Ie at AC-1, 400 V (EF001393): 800 A
- Rated operation current Ie at AC-3, 400 V (EF001392): 500 A
- Rated operation power at AC-3, 400 V (EF001364): 250 kW
- Rated operation current Ie at AC-4, 400 V (EF008495): 360 A
- Rated operation power at AC-4, 400 V (EF008496): 200 kW
- Rated operation power NEMA (EF011960): 298 kW
- Modular version (EF001126): No
- Width (EF000008): 160 mm
More info
▲General specifications
IEC/EN 60947-4-1
UL Category Control No.: NLDX
UL 60947-4-1
VDE 0660
UL File No.: E29096
UL/CSA
CSA file No. 012528
North America (UL listed, CSA certified)
EN 45545: Fire protection on railway vehicles
IEC 61373: Vibration and shock, tested for category 1 class B
CE marking
General
200 Operations/h
10 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
2 x (0.75 - 2.5) mm², Control circuit cables
1 x (0.75 - 2.5) mm², Control circuit cables
2/0 - 500 MCM, Main cables
M10, Terminal screw, Main connections
24 Nm, Main cable connection screw/bolt
Electrical rating
307 A at up to 525 V (Individual compensation, three-phase capacitors, open)
635 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
3120 A, LRA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
520 A, FLA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Short-circuit rating
30 kA, SCCR (UL/CSA)
800 A, max. Fuse, SCCR (UL/CSA)
100 kA, CB, SCCR (UL/CSA)
800/600 A, Class J, max. Fuse, SCCR (UL/CSA)
600 A, max. CB, SCCR (UL/CSA)
800/600 A, Class J, max. Fuse, SCCR (UL/CSA)
30/100 kA, Fuse, SCCR (UL/CSA)
30 kA, CB, SCCR (UL/CSA)
AC-1/Conventional thermal current Ith
Switching capacity
15 A, 600 V AC, (UL/CSA)
A600, AC operated (UL/CSA)
Magnet system
Sealing - Voltage drops (0.6 - 0.7 x Uc min: Contactor remains switched on
Sealing - Excess voltage (1.15 - 1.3 x Uc max): Contactor remains switched on
Sealing - Pick-up phase (0.7 x Uc min - 1.15 x Uc max): Contactor switches on with certainty
Sealing - Voltage drops (0.2 - 0.6 x Uc min ≤12 ms: Time is bridged successfully
Sealing - Voltage drops (0.2 - 0.6 x Uc min) > 12 ms: Drop-out of the contactor
Sealing - Voltage interruptions (0 - 0.2 x Uc min ≤ 10 ms: Time is bridged successfully
Sealing - Voltage interruptions 0 - 0.2 x Uc min) > 10 ms: Drop-out of the contactor
AC operated: 0.25 x US max - 0.6 x US min, AC operated
645 W, Pull-in power, Coil in a cold state and 1.0 x Us
645 W, Pull-in power, Coil in a cold state and 1.0 x Us
6.8 VA, Coil in a cold state and 1.0 x Us
6.8 VA, Coil in a cold state and 1.0 x Us