DILH2200/22(RAW250) 111793 Y7-111793 EATON ELECTRIC Contactor, 3p+2N/O+2N/C, 2200A/AC1
DILH2200/22(RAW250)
111793
Y7-111793
EATON - MOELLER
1 Pcs.
Automation > Power contactor, AC switching
Contactors more than 170 A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Siemens 3RT2025-2AN24 power contactor is engineered to control industrial motors up to 7.5 kW, providing secure switching and auxiliary contact flexibility for factory automation panels.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Power contactor
- product type designation: 3RT2
- General technical data size of contactor: S0
- ● function module for communication: No
- ● auxiliary switch: No
- ● at AC in hot operating state: 2.7 W
- ● at AC in hot operating state per pole: 0.9 W
- ● without load current share typical: 7.9 W
- ● of main circuit with degree of pollution 3 rated value: 690 V
- ● of main circuit rated value: 6 kV
- ● of auxiliary circuit rated value: 6 kV
- ● at AC: 7,5g / 5 ms, 4,7g / 10 ms
- ● at AC: 11,8g / 5 ms, 7,4g / 10 ms
- ● of contactor typical: 10 000 000
- ● of the contactor with added auxiliary switch block typical: 10 000 000
- reference code according to IEC 81346-2: Q
More info
▲General specifications
UL 60947-4-1
CE
IEC/EN 60947-4-1
CSA-C22.2 No. 60947-4-1-14
VDE 0660
UL File No.: E29096
IEC/EN 60947
UL Category Control No.: NLDX
CCC
UL
CSA
CSA File No.: 012528
Global
5,000,000 Operations (AC operated)
1000 mechanical Operations/h (DC operated)
8 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
General
Damp heat, cyclic, to IEC 60068-2-30
5,000,000 Operations (AC operated)
1000 mechanical Operations/h (DC operated)
8 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Climatic environmental conditions
2 x (0.75 - 2.5) mm², Control circuit cables
2 x (0.75 - 2.5) mm², Control circuit cables
M3.5, Terminal screw, Control circuit cables
2, Terminal screw, Control circuit cables, Pozidriv screwdriver
1.2 Nm, Screw terminals, Control circuit cables
Terminal capacities
2200 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
Electrical rating
2200 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
Short-circuit rating
Conventional thermal current Ith
15 A, 600 V AC, (UL/CSA)
P300, DC operated (UL/CSA)
Switching capacity
Sealing - Pick-up phase (0 - 0.7 x Uc min: Contactor does not switch on
Sealing - Voltage interruptions (0 - 0.2 x Uc min ≤ 10 ms: Time is bridged successfully
Sealing - Pick-up phase (0.7 x Uc min - 1.15 x Uc max): Contactor switches on with certainty
Sealing - Voltage drops (0.2 - 0.6 x Uc min ≤12 ms: Time is bridged successfully
Sealing - Voltage drops (0.6 - 0.7 x Uc min: Contactor remains switched on
Sealing - Excess voltage (1.15 - 1.3 x Uc max): Contactor remains switched on
Sealing - Voltage drops (0.2 - 0.6 x Uc min) > 12 ms: Drop-out of the contactor
AC operated: 0.2 x US max - 0.6 x US min, AC operated
0.7 - 1.15 V AC x Us
1600 VA, Pull-in power, Coil in a cold state and 1.0 x Us
1400 W, Pull-in power, Coil in a cold state and 1.0 x Us
17.3 W, Coil in a cold state and 1.0 x Us
36.5 VA, Coil in a cold state and 1.0 x Us
Magnet system
1600 VA, Pull-in power, Coil in a cold state and 1.0 x Us
1400 W, Pull-in power, Coil in a cold state and 1.0 x Us
17.3 W, Coil in a cold state and 1.0 x Us
36.5 VA, Coil in a cold state and 1.0 x Us