Short-circuit current rating (basic rating)
600 A, max. CB, SCCR (UL/CSA)
700 A, max. Fuse, SCCR (UL/CSA)
18 kA, SCCR (UL/CSA)
Short-circuit current rating (high fault at 480 V)
700 A, Class L, max. Fuse, SCCR (UL/CSA)
65 kA, CB, SCCR (UL/CSA)
250 A, max. CB, SCCR (UL/CSA)
18 kA, Fuse, SCCR (UL/CSA)
Short-circuit current rating (high fault at 600 V)
700 A, Class J, max. Fuse, SCCR (UL/CSA)
18 kA, Fuse, SCCR (UL/CSA)
600 A, max. CB, SCCR (UL/CSA)
18 kA, CB, SCCR (UL/CSA)
Short-circuit protection rating (type 1 coordination) at 1000 V
Short-circuit protection rating (type 1 coordination) at 400 V
Short-circuit protection rating (type 1 coordination) at 690 V
Short-circuit protection rating (type 2 coordination) at 1000 V
Short-circuit protection rating (type 2 coordination) at 400 V
Short-circuit protection rating (type 2 coordination) at 690 V
Rated operational current (Ie)
177 A at 690 V (Individual compensation, three-phase capacitors, open)
307 A at up to 525 V (Individual compensation, three-phase capacitors, open)
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
Rated operational current (Ie) at AC-3, 440 V
Rated operational current (Ie) at AC-3, 500 V
Rated operational current (Ie) at AC-3, 660 V, 690 V
Rated operational current (Ie) at AC-3, 1000 V
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V
Rated operational current (Ie) at AC-4, 440 V
Rated operational current (Ie) at AC-4, 500 V
Rated operational current (Ie) at AC-4, 660 V, 690 V
Rated operational current (Ie) at AC-4, 1000 V
Rated operational power at AC-3, 240 V, 50 Hz
Rated operational power at AC-3, 380/400 V, 50 Hz
Rated operational power at AC-3, 415 V, 50 Hz
Rated operational power at AC-3, 1000 V, 50 Hz
Rated operational power at AC-4, 220/230 V, 50 Hz
Rated operational power at AC-4, 240 V, 50 Hz
Rated operational power at AC-4, 415 V, 50 Hz
Rated operational power at AC-4, 440 V, 50 Hz
Rated operational power at AC-4, 500 V, 50 Hz
Rated operational power at AC-4, 660/690 V, 50 Hz
Rated operational voltage (Ue) at AC - max
Rated operational power at AC-4, 1000 V, 50 Hz
Safe isolation
1000 V AC, Between coil and contacts, According to EN 61140
Special purpose rating of definite purpose rating
300 A, FLA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
2160 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
1800 A, LRA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
360 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)