DILM1600/22(RAW250) 106727 Y7-106727 EATON ELECTRIC Contactor, 3p+2N/O+2N/C, 1600A/AC1
DILM1600/22(RAW250)
106727
Y7-106727
EATON - MOELLER
1 Pcs.
Automation > Power contactor, AC switching
Contactors more than 170 A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Contactor, 3p+2N/O+2N/C, 1600A/AC1 DILM1600/22(RAW250) manufactured by Eaton Moeller is an extremely heavy-duty switching device built for massive industrial power distribution and high-capacity electrical loads. It handles heavy-duty switching demands in large-scale energy infrastructure and heavy industrial plants. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Manufacturer: Eaton Moeller
- Part Number: DILM1600/22(RAW250)
- Auxiliary Contacts: 2 N/O, 2 NC
- Power: 900 kW at 400 V
- Connection: Screw connection
More info
▲General specifications
IEC/EN 60947-4-1
CE
UL
IEC/EN 60947
CSA File No.: 012528
UL 60947-4-1
UL Category Control No.: NLDX
CSA
VDE 0660
UL File No.: E29096
CSA-C22.2 No. 60947-4-1-14
General
5,000,000 Operations (DC operated)
1000 mechanical Operations/h (AC operated)
8 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
AC-3: Normal AC induction motors: starting, switch off during running
Climatic environmental conditions
Damp heat, cyclic, to IEC 60068-2-30
Terminal capacities
1 x (0.75 - 2.5) mm², Control circuit cables
2 x (0.75 - 2.5) mm², Control circuit cables
M12, Terminal screw, Main connections
1.2 Nm, Screw terminals, Control circuit cables
Electrical rating
Short-circuit rating
85 kA, SCCR (UL/CSA)
2000 A, max. Fuse, SCCR (UL/CSA)
85 kA, Fuse, SCCR (UL/CSA)
Conventional thermal current Ith
Switching capacity
15 A, 600 V AC, (UL/CSA)
A600, AC operated (UL/CSA)
Magnet system
Sealing - Pick-up phase (0.7 x Uc min - 1.15 x Uc max): Contactor switches on with certainty
Sealing - Voltage interruptions 0 - 0.2 x Uc min) > 10 ms: Drop-out of the contactor
Sealing - Voltage drops (0.2 - 0.6 x Uc min ≤12 ms: Time is bridged successfully
Sealing - Voltage interruptions (0 - 0.2 x Uc min ≤ 10 ms: Time is bridged successfully
Sealing - Voltage drops (0.2 - 0.6 x Uc min) > 12 ms: Drop-out of the contactor
Sealing - Excess voltage (1.15 - 1.3 x Uc max): Contactor remains switched on
Sealing - Pick-up phase (0 - 0.7 x Uc min: Contactor does not switch on
0.2 x US max - 0.6 x US min, DC operated
0.7 - 1.15 V DC x Us
1600 VA, Pull-in power, Coil in a cold state and 1.0 x Us
1400 W, Pull-in power, Coil in a cold state and 1.0 x Us
17.3 W, Coil in a cold state and 1.0 x Us
17.3 W, Coil in a cold state and 1.0 x Us