View larger
DILM250-S/22(220-240V50/60HZ) 274190 Y7-274190 EATON ELECTRIC Contactor, 3p+2N/O+2N/C, 132kW/400V/AC3
DILM250-S/22(220-240V50/60HZ)
274190
Y7-274190
EATON - MOELLER
1 Pcs.
Automation > Power contactor, AC switching
Contactors more than 170 A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for massive industrial motor control, the Eaton Moeller DILM250-S/22(220-240V50/60HZ) contactor provides high-capacity power switching for heavy manufacturing equipment. Heavy-duty contactors are essential for managing immense startup currents and continuous operational loads in large industrial plants.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Manufacturer: Eaton Moeller
- Model Code: DILM250-S/22(220-240V50/60HZ)
- Catalogue Code: 274190
- Switching Capacity: 132 kW at 400 V AC-3
- Auxiliary Contacts: 2 N/O and 2 N/C
- Control Voltage: 220-240 V 50/60 Hz AC operation
- Connection: Screw connection
More info
▲General specifications
UL File No.: E29096
UL Category Control No.: NLDX
VDE 0660
UL 60947-4-1
CSA Class No.: 3211-04
UL/CSA
CSA File No. 1017510
North America (UL listed, CSA certified)
EN 45545: Fire protection on railway vehicles
IEC 61373: Vibration and shock, tested for category 1 class B
CE marking
General
200 Operations/h
8 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
AC-3: Normal AC induction motors: starting, switch off during running
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
2 x (0.75 - 2.5) mm², Control circuit cables
1 x (0.75 - 2.5) mm², Control circuit cables
18 - 14, Control circuit cables
M3.5, Terminal screw, Control circuit cables
24 Nm, Main cable connection screw/bolt
Electrical rating
133 A at 690 V (Individual compensation, three-phase capacitors, open)
500 V AC, Between the contacts, According to EN 61140
300 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
1800 A, LRA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
250 A, FLA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Short-circuit rating
18 kA, SCCR (UL/CSA)
600 A, max. CB, SCCR (UL/CSA)
65 kA, CB, SCCR (UL/CSA)
18 kA, Fuse, SCCR (UL/CSA)
700 A, Class L, max. Fuse, SCCR (UL/CSA)
700 A, Class L/450 A, Class J, max. Fuse, SCCR (UL/CSA)
18/100 kA, Fuse, SCCR (UL/CSA)
18 kA, Fuse, SCCR (UL/CSA)
700 A, Class J, max. Fuse, SCCR (UL/CSA)
600 A, max. CB, SCCR (UL/CSA)
700 A, Class L/450 A, Class J, max. Fuse, SCCR (UL/CSA)
18/100 kA, Fuse, SCCR (UL/CSA)
Conventional thermal current Ith
Switching capacity
15 A, 600 V AC, (UL/CSA)
A600, AC operated (UL/CSA)
Magnet system
Sealing - Pick-up phase (0.7 x Uc min - 1.15 x Uc max): Contactor switches on with certainty
Sealing - Voltage interruptions (0 - 0.2 x Uc min ≤ 10 ms: Time is bridged successfully
Sealing - Voltage interruptions 0 - 0.2 x Uc min) > 10 ms: Drop-out of the contactor
Sealing - Voltage drops (0.2 - 0.6 x Uc min ≤12 ms: Time is bridged successfully
Sealing - Voltage drops (0.2 - 0.6 x Uc min) > 12 ms: Drop-out of the contactor
Sealing - Excess voltage (1.15 - 1.3 x Uc max): Contactor remains switched on
Sealing - Voltage drops (0.6 - 0.7 x Uc min: Contactor remains switched on
AC operated: 0.25 x US max - 0.6 x US min, AC operated
360 VA, Pull-in power, Coil in a cold state and 1.0 x Us
325 W, Pull-in power, Coil in a cold state and 1.0 x Us
4.8 W, Coil in a cold state and 1.0 x Us
4.8 W, Coil in a cold state and 1.0 x Us