View larger
DILM65(24V50HZ) 277881 Y7-277881 EATON ELECTRIC Contactor, 3p, 30kW/400V/AC3
DILM65(24V50HZ)
277881
Y7-277881
EATON - MOELLER
1 Pcs.
Automation > Power contactor, AC switching
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller DILM65(24V50HZ) is a high-capacity power contactor built to manage heavy industrial motor loads and large electrical distribution systems. Industrial automation setups use such devices to ensure reliable, high-frequency circuit making and breaking. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz: 24 V
- Rated control supply voltage AC 60 Hz: 0 V
- Rated control supply voltage DC: 0 V
- Voltage type for actuating: AC
- Number of normally open contacts as main contact: 3
- Type of electrical connection of main circuit: Screw connection
- Operating voltage AC 50 Hz: 230 V
- Operating voltage AC 60 Hz: 230 V
- Rated operation current Ie at AC-1, 400 V: 98 A
- Rated operation current Ie at AC-3, 400 V: 65 A
- Rated operation power at AC-3, 400 V: 30 kW
- Rated operation current Ie at AC-4, 400 V: 25 A
- Rated operation power at AC-4, 400 V: 12 kW
- Rated operation power NEMA: 37 kW
- Modular version: No
- Width: 55 mm
More info
▲General specifications
VDE 0660
CSA-C22.2 No. 60947-4-1-14
CE
IEC/EN 60947
UL
IEC/EN 60947-4-1
UL 60947-4-1
UL File No.: E29096
UL Category Control No.: NLDX
CSA Class No.: 2411-03, 3211-04
CSA
Features & Functions
General
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
AC-3: Normal AC induction motors: starting, switch off during running
Ambient conditions, mechanical
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Climatic environmental conditions
Damp heat, cyclic, to IEC 60068-2-30
Electro Magnetic Compatibility
Terminal capacities
1 x (0.75 - 35) mm², Main cables
1 x (0.75 - 2.5) mm², Control circuit cables
2 x (0.75 - 25) mm², Main cables
1 x (0.75 - 4) mm², Control circuit cables
2 x (0.75 - 2.5) mm², Control circuit cables
1 x (0.75 - 16) mm², Main cables
Single 14 - 1, double 14 - 2, Main cables
2 x (16 - 35) mm², Main cables
M6, Terminal screw, Main cables
0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver
3.3 Nm, Screw terminals, Main cables
Electrical Rating
Short-circuit rating
10 kA, SCCR (UL/CSA)
250 A, max. CB, SCCR (UL/CSA)
65 kA, CB, SCCR (UL/CSA)
250/150 A, Class J, max. Fuse, SCCR (UL/CSA)
100 A, max. CB, SCCR (UL/CSA)
30 kA, CB, SCCR (UL/CSA)
250 A, max. CB, SCCR (UL/CSA)
30/100 kA, Fuse, SCCR (UL/CSA)
Conventional thermal current
Switching capacity
Switching time
Magnet system
4.1 W, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
4.1 W, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Motor Rating
Communication
Contacts
Safety
440 V AC, Between coil and contacts, According to EN 61140
Special purpose ratings
88 A (600V 60Hz 3phase, 347V 60Hz 1phase)
390 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
40 A, 480 V 60 Hz 3-ph, (UL/CSA)
15 HP, 240 V 60 Hz 3-ph, (UL/CSA)
41 A, 600 V 60 Hz 3-ph, (UL/CSA)
30 HP, 480 V 60 Hz 3-ph, (UL/CSA)
10 HP, 200 V 60 Hz 3-ph, (UL/CSA)
32.2 A, 200 V 60 Hz 3-ph, (UL/CSA)
40 HP, 600 V 60 Hz 3-ph, (UL/CSA)
88 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
88 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)