View larger
DILM50(230V50HZ,240V60HZ) 277830 Y7-277830 EATON ELECTRIC 277830 DILM50(230V50HZ,240V60HZ)
DILM50(230V50HZ,240V60HZ)
277830
Y7-277830
EATON - MOELLER
1 Pcs.
Automation > Power contactor, AC switching
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Operating as a robust electromechanical switch, the DILM50(230V50HZ,240V60HZ) 277830 Y7-277830 EATON ELECTRIC 277830 DILM50(230V50HZ,240V60HZ) is engineered for frequent starting and stopping of electric motors and high-power industrial loads. Industrial contactors provide safe remote control over primary power paths in manufacturing automation and motor control centers.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 230 V
- Rated control supply voltage AC 60 Hz (EF003979): 240 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Number of normally open contacts as main contact (EF001374): 3
- Type of electrical connection of main circuit (EF006819): Screw connection
- Operating voltage AC 50 Hz (EF008206): 230 V
- Operating voltage AC 60 Hz (EF008207): 230 V
- Rated operation current Ie at AC-1, 400 V (EF001393): 80 A
- Rated operation current Ie at AC-3, 400 V (EF001392): 50 A
- Rated operation power at AC-3, 400 V (EF001364): 22 kW
- Rated operation current Ie at AC-4, 400 V (EF008495): 21 A
- Rated operation power at AC-4, 400 V (EF008496): 10 kW
- Rated operation power NEMA (EF011960): 29.8 kW
- Modular version (EF001126): No
- Width (EF000008): 55 mm
More info
▲General specifications
IEC 60947-4-1
CSA Std. C22.2 No. 14-05
UL 508
CSA Certified
UL Listed
IEC/EN 60947-4-1
UL 60947-4-1
CSA File No.: 012528
UL File No.: E29096
CE
UL Category Control No.: NLDX
CSA Class No.: 2411-03, 3211-04
VDE 0660
CSA
IEC/EN 60947
CSA-C22.2 No. 60947-4-1-14
UL
Features & Functions
General
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Ambient conditions, mechanical
5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
Climatic environmental conditions
Damp heat, cyclic, to IEC 60068-2-30
Electro Magnetic Compatibility
Terminal capacities
1 x (0.75 - 35) mm², Main cables
2 x (0.75 - 2.5) mm², Control circuit cables
2 x (0.75 - 25) mm², Main cables
1 x (0.75 - 4) mm², Control circuit cables
1 x (0.75 - 16) mm², Main cables
2 x (0.75 - 2.5) mm², Control circuit cables
Single 14 - 1, double 14 - 2, Main cables
1 x (16 - 50) mm², Main cables
M3.5, Terminal screw, Control circuit cables
0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver
1.2 Nm, Screw terminals, Control circuit cables
Electrical Rating
Short-circuit rating
250 A, max. CB, SCCR (UL/CSA)
250 A, max. Fuse, SCCR (UL/CSA)
250/150 A, Class J, max. Fuse, SCCR (UL/CSA)
65 kA, CB, SCCR (UL/CSA)
30/100 kA, Fuse, SCCR (UL/CSA)
250/150 A, Class J, max. Fuse, SCCR (UL/CSA)
30/100 kA, Fuse, SCCR (UL/CSA)
250 A, max. CB, SCCR (UL/CSA)
Conventional thermal current
Switching capacity
Switching time
Magnet system
4.1 W, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
4.1 W, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Motor Rating
Communication
Contacts
Safety
440 V AC, Between the contacts, According to EN 61140
Special purpose ratings
79 A (480V 60Hz 3phase, 277V 60Hz 1phase)
41 A, 600 V 60 Hz 3-ph, (UL/CSA)
30 HP, 480 V 60 Hz 3-ph, (UL/CSA)
10 HP, 200 V 60 Hz 3-ph, (UL/CSA)
40 HP, 600 V 60 Hz 3-ph, (UL/CSA)
40 A, 480 V 60 Hz 3-ph, (UL/CSA)
42 A, 240 V 60 Hz 3-ph, (UL/CSA)
15 HP, 240 V 60 Hz 3-ph, (UL/CSA)
79 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
74 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)