View larger
DILL20(230V50HZ,240V60HZ) 104408 Y7-104408 EATON ELECTRIC Contactor, 3p, 20A, for lamp load (HQL)
DILL20(230V50HZ,240V60HZ)
104408
Y7-104408
EATON - MOELLER
1 Pcs.
Automation > Power contactor, AC switching
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller part number DILL20(230V50HZ,240V60HZ) (Y7-104408) is a specialized lighting contactor configured for controlling high-intensity discharge lamp loads and similar lighting infrastructure. Facilities management systems and commercial electrical panels rely on specialized contactors to safely manage large lighting banks. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 230 V
- Rated control supply voltage AC 60 Hz (EF003979): 240 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Number of normally open contacts as main contact (EF001374): 3
- Type of electrical connection of main circuit (EF006819): Screw connection
- Operating voltage AC 50 Hz (EF008206): 230 V
- Operating voltage AC 60 Hz (EF008207): 230 V
- Rated operation current Ie at AC-1, 400 V (EF001393): 20 A
- Rated operation current Ie at AC-3, 400 V (EF001392): 0 A
- Rated operation power at AC-3, 400 V (EF001364): 0 kW
- Rated operation current Ie at AC-4, 400 V (EF008495): 0 A
- Rated operation power at AC-4, 400 V (EF008496): 0 kW
- Rated operation power NEMA (EF011960): 0 kW
- Modular version (EF001126): No
- Width (EF000008): 45 mm
More info
▲General specifications
EN 60947-4-1
CSA Std. C22.2 No. 14-05
UL 508
VDE
CE
CSA Class No.: 3211-04
VDE 0660
CSA-C22.2 No. 60947-4-1-14
UL Category Control No.: NLDX
IEC/EN 60947
CSA File No.: 012528
CSA
IEC/EN 60947-4-1
UL 60947-4-1
UL
UL File No.: E29096
Features & Functions
General
60 electrical Operations/h
Ambient conditions, mechanical
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Electro Magnetic Compatibility
Electrical Rating
12 A (Low-pressure sodium lamps)
20 A (High-pressure mercury vapor lamps)
27 A at AC-3, 220/230 V
35 A (Conventional reactor starter circuit)
20 A at AC-1, 220 V 230 V
20 A (Electronic upstream devices)
20 A (High-pressure sodium lamps)
20 A at AC-1, 380 V 400 V
27 A (Filament bulbs)
35 A (Fluorescent lamp load - duo circuit)
20 A (Metal-halide lamps)
Short-circuit rating
5 kA, SCCR (UL/CSA)
125 A, max. CB, SCCR (UL/CSA)
32 A, max. CB, SCCR (UL/CSA)
22 kA, CB, SCCR (UL/CSA)
125 A, Class J, max. Fuse, SCCR (UL/CSA)
32 A, max. CB, SCCR (UL/CSA)
125 A, Class J, max. Fuse, SCCR (UL/CSA)
22 kA, CB, SCCR (UL/CSA)
Switching capacity
Switching time
Magnet system
7.1 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
8.7 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Communication
Contacts
Special purpose ratings
40 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)