View larger
DILL18(400V50HZ,440V60HZ) 104406 Y7-104406 EATON ELECTRIC Contactor, 3p, 18A, for lamp load (HQL)
DILL18(400V50HZ,440V60HZ)
104406
Y7-104406
EATON - MOELLER
1 Pcs.
Automation > Power contactor, AC switching
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The DILL18(400V50HZ,440V60HZ) 104406 Y7-104406 EATON ELECTRIC Contactor, 3p, 18A, for lamp load (HQL) is a specialized switching device designed specifically for lighting installations and high-intensity discharge lamp loads. It manages frequent switching cycles required in commercial and industrial lighting distribution networks.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 400 V
- Rated control supply voltage AC 60 Hz (EF003979): 440 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Number of normally open contacts as main contact (EF001374): 3
- Type of electrical connection of main circuit (EF006819): Screw connection
- Operating voltage AC 50 Hz (EF008206): 230 V
- Operating voltage AC 60 Hz (EF008207): 230 V
- Rated operation current Ie at AC-1, 400 V (EF001393): 18 A
- Rated operation current Ie at AC-3, 400 V (EF001392): 0 A
- Rated operation power at AC-3, 400 V (EF001364): 0 kW
- Rated operation current Ie at AC-4, 400 V (EF008495): 0 A
- Rated operation power at AC-4, 400 V (EF008496): 0 kW
- Rated operation power NEMA (EF011960): 0 kW
- Modular version (EF001126): No
- Width (EF000008): 45 mm
More info
▲General specifications
IEC 60947-4-1
EN 60947-4-1
UL 508
VDE
VDE 0660
UL
IEC/EN 60947
CSA
Features & Functions
General
60 electrical Operations/h
Ambient conditions, mechanical
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Electro Magnetic Compatibility
Electrical Rating
21 A (Filament bulbs)
18 A (High-pressure sodium lamps)
18 A (Electronic upstream devices)
21 A at AC-3, 220/230 V
16 A (Mercury blended lamps)
18 A at AC-1, 220 V 230 V
18 A at AC-1, 380 V 400 V
26 A (Conventional reactor starter circuit)
18 A (Metal-halide lamps)
10 A (Low-pressure sodium lamps)
18 A (High-pressure mercury vapor lamps)
Short-circuit rating
Switching time
Magnet system
7.1 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
8.7 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz