View larger
DILL18(24V50HZ) 104404 Y7-104404 EATON ELECTRIC Contactor, 3p, 18A, for lamp load (HQL)
DILL18(24V50HZ)
104404
Y7-104404
EATON - MOELLER
1 Pcs.
Automation > Power contactor, AC switching
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered specifically for specialized lighting applications, the Eaton Moeller DILL18(24V50HZ) 104404 Y7-104404 EATON ELECTRIC Contactor, 3p, 18A, for lamp load (HQL) serves as a dedicated switching component for high-intensity discharge and commercial illumination systems.
Such devices provide reliable cycling and thermal management required when handling specialized electrical lighting loads within distribution boards. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 24 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Number of normally open contacts as main contact (EF001374): 3
- Type of electrical connection of main circuit (EF006819): Screw connection
- Operating voltage AC 50 Hz (EF008206): 230 V
- Operating voltage AC 60 Hz (EF008207): 230 V
- Rated operation current Ie at AC-1, 400 V (EF001393): 18 A
- Rated operation current Ie at AC-3, 400 V (EF001392): 0 A
- Rated operation power at AC-3, 400 V (EF001364): 0 kW
- Rated operation current Ie at AC-4, 400 V (EF008495): 0 A
- Rated operation power at AC-4, 400 V (EF008496): 0 kW
- Rated operation power NEMA (EF011960): 0 kW
- Modular version (EF001126): No
- Width (EF000008): 45 mm
More info
▲General specifications
UL 508
EN 60947-4-1
CSA Std. C22.2 No. 14-05
VDE
IEC/EN 60947
CSA
VDE 0660
UL 60947-4-1
IEC/EN 60947-4-1
UL Category Control No.: NLDX
CSA Class No.: 3211-04
CE
CSA-C22.2 No. 60947-4-1-14
UL File No.: E29096
CSA File No.: 012528
UL
Features & Functions
General
60 electrical Operations/h
Ambient conditions, mechanical
Climatic environmental conditions
Damp heat, cyclic, to IEC 60068-2-30
Electro Magnetic Compatibility
Electrical Rating
26 A (Fluorescent lamp load - duo circuit)
18 A (High-pressure sodium lamps)
18 A at AC-1, 220 V 230 V
16 A (Mercury blended lamps)
18 A (Electronic upstream devices)
18 A (Metal-halide lamps)
26 A (Conventional reactor starter circuit)
18 A (High-pressure mercury vapor lamps)
10 A (Low-pressure sodium lamps)
21 A at AC-3, 220/230 V
21 A (Filament bulbs)
Short-circuit rating
5 kA, SCCR (UL/CSA)
125 A, max. CB, SCCR (UL/CSA)
100 kA, Fuse, SCCR (UL/CSA)
32 A, max. CB, SCCR (UL/CSA)
22 kA, CB, SCCR (UL/CSA)
22 kA, CB, SCCR (UL/CSA)
100 A, Class J, max. Fuse, SCCR (UL/CSA)
100 kA, Fuse, SCCR (UL/CSA)
Switching capacity
Switching time
Magnet system
7.1 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
8.7 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Communication
Contacts
Special purpose ratings
35 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)