View larger
DILM40(230V50/60HZ) 277774 Y7-277774 EATON ELECTRIC Contactor, 3p, 18.5kW/400V/AC3
DILM40(230V50/60HZ)
277774
Y7-277774
EATON - MOELLER
1 Pcs.
Automation > Power contactor, AC switching
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller DILM40(230V50/60HZ) is a robust power contactor built to handle significant electrical currents in industrial automation setups. They are commonly implemented in motor control centers to manage heavy manufacturing operations. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Manufacturer: Eaton Moeller
- Manufacturer part number: DILM40(230V50/60HZ)
- Catalogue code: 277774
- Catalogue title: DILM40(230V50/60HZ) 277774 Y7-277774 EATON ELECTRIC Contactor, 3p, 18.5kW/400V/AC3
- Product description: General specifications Product Name Eaton Moeller® series DILM contactor Catalog Number 277774 Model Code DILM40(230V50/60HZ) EAN 4015082777746 Product Length/Depth 132.1 mm Product Height 115 mm Product Width 55 mm Prod
- Manufacturer summary: Contactor, 3p, 18.5kW/400V/AC3 DILM40(230V50/60HZ) Eaton Moeller® series DILM Contactor, 3 pole, 380 V 400 V 18.5 kW, 230 V 50/60 Hz, AC operation, Screw terminals
More info
▲General specifications
CSA Std. C22.2 No. 14-05
EN 60947-4-1
UL 508
VDE
CSA File No.: 012528
CSA Class No.: 2411-03, 3211-04
CE
IEC/EN 60947
VDE 0660
CSA
UL Category Control No.: NLDX
IEC/EN 60947-4-1
CSA-C22.2 No. 60947-4-1-14
UL File No.: E29096
UL
UL 60947-4-1
Features & Functions
General
10,000,000 Operations (AC operated)
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
Ambient conditions, mechanical
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
Climatic environmental conditions
Damp heat, cyclic, to IEC 60068-2-30
Electro Magnetic Compatibility
Terminal capacities
1 x (0.75 - 35) mm², Main cables
2 x (0.75 - 25) mm², Main cables
2 x (0.75 - 2.5) mm², Control circuit cables
1 x (0.75 - 4) mm², Control circuit cables
2 x (0.75 - 2.5) mm², Control circuit cables
2 x (0.75 - 16) mm², Main cables
18 - 14, Control circuit cables
1 x (16 - 50) mm², Main cables
M3.5, Terminal screw, Control circuit cables
2, Terminal screw, Pozidriv screwdriver
3.3 Nm, Screw terminals, Main cables
Electrical Rating
Short-circuit rating
10 kA, SCCR (UL/CSA)
250 A, max. Fuse, SCCR (UL/CSA)
30/100 kA, Fuse, SCCR (UL/CSA)
250/150 A, Class J, max. Fuse, SCCR (UL/CSA)
65 kA, CB, SCCR (UL/CSA)
250 A, max. CB, SCCR (UL/CSA)
250/150 A, Class J, max. Fuse, SCCR (UL/CSA)
30 kA, CB, SCCR (UL/CSA)
Conventional thermal current
Switching capacity
Switching time
Magnet system
168 VA, Dual-frequency coil in a cold state and 1.0 x Us
154 VA, Dual-frequency coil in a cold state and 1.0 x Us
14 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
22 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Motor Rating
Communication
Contacts
Safety
440 V AC, Between coil and contacts, According to EN 61140
Special purpose ratings
79 A (480V 60Hz 3phase, 277V 60Hz 1phase)
25.3 A, 200 V 60 Hz 3-ph, (UL/CSA)
25 HP, 480 V 60 Hz 3-ph, (UL/CSA)
34 A, 480 V 60 Hz 3-ph, (UL/CSA)
7.5 HP, 200 V 60 Hz 3-ph, (UL/CSA)
10 HP, 240 V 60 Hz 3-ph, (UL/CSA)
28 A, 240 V 60 Hz 3-ph, (UL/CSA)
32 A, 600 V 60 Hz 3-ph, (UL/CSA)
79 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)