Industrial motor control centers integrate robust devices like the Eaton Moeller DILMF150(RAC240) contactor to manage heavy loads and ensure reliable power switching across manufacturing workflows. It safely routes high operating currents via remote signals.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 190 V
- Rated control supply voltage AC 60 Hz (EF003979): 190 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Number of normally open contacts as main contact (EF001374): 3
- Type of electrical connection of main circuit (EF006819): Screw connection
- Operating voltage AC 50 Hz (EF008206): 230 V
- Operating voltage AC 60 Hz (EF008207): 230 V
- Rated operation current Ie at AC-1, 400 V (EF001393): 160 A
- Rated operation current Ie at AC-3, 400 V (EF001392): 150 A
- Rated operation power at AC-3, 400 V (EF001364): 75 kW
- Rated operation current Ie at AC-4, 400 V (EF008495): 65 A
- Rated operation power at AC-4, 400 V (EF008496): 33 kW
- Rated operation power NEMA (EF011960): 93 kW
- Modular version (EF001126): No
- Width (EF000008): 90 mm
More info
▲General specifications
CE
CSA File No.: 012528
UL 60947-4-1
CSA
UL
UL Category Control No.: NLDX
CSA Class No.: 2411-03, 3211-04
CSA-C22.2 No. 60947-4-1-14
UL File No.: E29096
Features & Functions
General
Also motors with efficiency class IE3
AC-3: Normal AC induction motors: starting, switch off during running
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
Climatic environmental conditions
Electro Magnetic Compatibility
Electrical Rating
Short-circuit rating
10 kA, SCCR (UL/CSA)
600 A, max. Fuse, SCCR (UL/CSA)
300/300 A, Class J, max. Fuse, SCCR (UL/CSA)
250 A, max. CB, SCCR (UL/CSA)
30/100 kA, Fuse, SCCR (UL/CSA)
300/600 A, Class J, max. Fuse, SCCR (UL/CSA)
30 kA, CB, SCCR (UL/CSA)
350 A, max. CB, SCCR (UL/CSA)
Conventional thermal current
Switching capacity
Switching time
Magnet system
2.3 W, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
Motor Rating
Communication
Contacts
Special purpose ratings
160 A (600V 60Hz 3phase, 347V 60Hz 1phase)
150 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
30 HP, 200 V 60 Hz 3-ph, (UL/CSA)
40 HP, 240 V 60 Hz 3-ph, (UL/CSA)
92 A, 200 V 60 Hz 3-ph, (UL/CSA)
100 HP, 600 V 60 Hz 3-ph, (UL/CSA)
75 HP, 480 V 60 Hz 3-ph, (UL/CSA)
99 A, 600 V 60 Hz 3-ph, (UL/CSA)
96 A, 480 V 60 Hz 3-ph, (UL/CSA)
540 A, LRA 600 V 60 Hz 3phase; (CSA)
90 A, FLA 600 V 60 Hz 3phase; (CSA)
540 A, LRA 480 V 60 Hz 3phase; (CSA)
160 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
160 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)