View larger
DILL12(400V50HZ,440V60HZ) 104403 Y7-104403 EATON ELECTRIC Contactor, 3p, 12A, for lamp load (HQL)
DILL12(400V50HZ,440V60HZ)
104403
Y7-104403
EATON - MOELLER
1 Pcs.
Automation > Power contactor, AC switching
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller DILL12(400V50HZ,440V60HZ) is a specialized lighting contactor designed for switching high-intensity discharge lamp loads.
Lighting contactors safely manage the high inrush currents associated with commercial and industrial lighting systems without premature contact wear.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 400 V
- Rated control supply voltage AC 60 Hz (EF003979): 440 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Number of normally open contacts as main contact (EF001374): 3
- Type of electrical connection of main circuit (EF006819): Screw connection
- Operating voltage AC 50 Hz (EF008206): 230 V
- Operating voltage AC 60 Hz (EF008207): 230 V
- Rated operation current Ie at AC-1, 400 V (EF001393): 12 A
- Rated operation current Ie at AC-3, 400 V (EF001392): 0 A
- Rated operation power at AC-3, 400 V (EF001364): 0 kW
- Rated operation current Ie at AC-4, 400 V (EF008495): 0 A
- Rated operation power at AC-4, 400 V (EF008496): 0 kW
- Rated operation power NEMA (EF011960): 0 kW
- Modular version (EF001126): No
- Width (EF000008): 45 mm
More info
▲General specifications
IEC 60947-4-1
CSA Std. C22.2 No. 14-05
EN 60947-4-1
VDE
IEC/EN 60947
UL
CSA
VDE 0660
Features & Functions
General
60 mechanical Operations/h (AC operated)
Ambient conditions, mechanical
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Electro Magnetic Compatibility
Electrical Rating
12 A (Mercury blended lamps)
7.5 A (Low-pressure sodium lamps)
20 A (Fluorescent lamp load - duo circuit)
12 A (Metal-halide lamps)
12 A (High-pressure sodium lamps)
12 A at AC-1, 220 V 230 V
12 A at AC-1, 380 V 400 V
20 A (Conventional reactor starter circuit)
12 A (Electronic upstream devices)
14 A at AC-3, 220/230 V
12 A (High-pressure mercury vapor lamps)
Short-circuit rating
Switching time
Magnet system
7.1 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
8.7 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz