View larger
DILL12(230V50HZ,240V60HZ) 104402 Y7-104402 EATON ELECTRIC Contactor, 3p, 12A, for lamp load (HQL)
DILL12(230V50HZ,240V60HZ)
104402
Y7-104402
EATON - MOELLER
1 Pcs.
Automation > Power contactor, AC switching
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Specialized for lighting management, the Eaton Moeller DILL12(230V50HZ,240V60HZ) contactor is engineered to handle high inrush currents typical of discharge lamps and high-pressure mercury vapor systems. These switching devices ensure reliable operation in commercial and industrial facility lighting networks.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 230 V
- Rated control supply voltage AC 60 Hz (EF003979): 240 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Number of normally open contacts as main contact (EF001374): 3
- Type of electrical connection of main circuit (EF006819): Screw connection
- Operating voltage AC 50 Hz (EF008206): 230 V
- Operating voltage AC 60 Hz (EF008207): 230 V
- Rated operation current Ie at AC-1, 400 V (EF001393): 12 A
- Rated operation current Ie at AC-3, 400 V (EF001392): 0 A
- Rated operation power at AC-3, 400 V (EF001364): 0 kW
- Rated operation current Ie at AC-4, 400 V (EF008495): 0 A
- Rated operation power at AC-4, 400 V (EF008496): 0 kW
- Rated operation power NEMA (EF011960): 0 kW
- Modular version (EF001126): No
- Width (EF000008): 45 mm
More info
▲General specifications
CSA Class No.: 3211-04
CSA
IEC/EN 60947-4-1
UL 60947-4-1
CE
CSA-C22.2 No. 60947-4-1-14
IEC/EN 60947
UL File No.: E29096
CSA File No.: 012528
UL
UL Category Control No.: NLDX
Features & Functions
General
60 electrical Operations/h
Ambient conditions, mechanical
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Electro Magnetic Compatibility
Electrical Rating
12 A at AC-1, 220 V 230 V
20 A (Conventional reactor starter circuit)
20 A (Fluorescent lamp load - duo circuit)
14 A at AC-3, 220/230 V
12 A (Metal-halide lamps)
12 A (Electronic upstream devices)
12 A (High-pressure mercury vapor lamps)
12 A (High-pressure sodium lamps)
7.5 A (Low-pressure sodium lamps)
14 A (Filament bulbs)
12 A (Mercury blended lamps)
Short-circuit rating
5 kA, SCCR (UL/CSA)
125 A, max. Fuse, SCCR (UL/CSA)
70 A, Class J, max. Fuse, SCCR (UL/CSA)
22 kA, CB, SCCR (UL/CSA)
32 A, max. CB, SCCR (UL/CSA)
32 A, max. CB, SCCR (UL/CSA)
100 kA, Fuse, SCCR (UL/CSA)
22 kA, CB, SCCR (UL/CSA)
Switching capacity
Switching time
Magnet system
7.1 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
8.7 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Communication
Contacts
Special purpose ratings
24 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)