View larger
DILL12(24V50HZ) 104401 Y7-104401 EATON ELECTRIC Contactor, 3p, 12A, for lamp load (HQL)
DILL12(24V50HZ)
104401
Y7-104401
EATON - MOELLER
1 Pcs.
Automation > Power contactor, AC switching
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller DILL12(24V50HZ) contactor is specialized for managing high-inrush lighting loads and specialized electrical distribution circuits. Such devices prevent premature contact degradation caused by repetitive high-current surges in commercial and industrial lighting setups.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 24 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Number of normally open contacts as main contact (EF001374): 3
- Type of electrical connection of main circuit (EF006819): Screw connection
- Operating voltage AC 50 Hz (EF008206): 230 V
- Operating voltage AC 60 Hz (EF008207): 230 V
- Rated operation current Ie at AC-1, 400 V (EF001393): 12 A
- Rated operation current Ie at AC-3, 400 V (EF001392): 0 A
- Rated operation power at AC-3, 400 V (EF001364): 0 kW
- Rated operation current Ie at AC-4, 400 V (EF008495): 0 A
- Rated operation power at AC-4, 400 V (EF008496): 0 kW
- Rated operation power NEMA (EF011960): 0 kW
- Modular version (EF001126): No
- Width (EF000008): 45 mm
More info
▲General specifications
CSA Class No.: 3211-04
UL File No.: E29096
CSA File No.: 012528
IEC/EN 60947
UL 60947-4-1
UL Category Control No.: NLDX
UL
VDE 0660
CSA-C22.2 No. 60947-4-1-14
CSA
IEC/EN 60947-4-1
Features & Functions
General
60 electrical Operations/h
Ambient conditions, mechanical
Climatic environmental conditions
Damp heat, cyclic, to IEC 60068-2-30
Electro Magnetic Compatibility
Electrical Rating
12 A (High-pressure mercury vapor lamps)
12 A (Metal-halide lamps)
7.5 A (Low-pressure sodium lamps)
14 A (Filament bulbs)
12 A (Electronic upstream devices)
12 A (Mercury blended lamps)
14 A at AC-3, 220/230 V
12 A at AC-1, 380 V 400 V
12 A (High-pressure sodium lamps)
20 A (Conventional reactor starter circuit)
20 A (Fluorescent lamp load - duo circuit)
Short-circuit rating
125 A, max. Fuse, SCCR (UL/CSA)
125 A, max. CB, SCCR (UL/CSA)
100 kA, Fuse, SCCR (UL/CSA)
22 kA, CB, SCCR (UL/CSA)
32 A, max. CB, SCCR (UL/CSA)
22 kA, CB, SCCR (UL/CSA)
100 kA, Fuse, SCCR (UL/CSA)
32 A, max. CB, SCCR (UL/CSA)
Switching capacity
Switching time
Magnet system
0.8 - 1.1 V AC x Uc
0.7 - 1.15 V DC x Us
7.1 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
8.7 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Communication
Contacts
Special purpose ratings
24 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)