M22-CK10 216384 Y7-216384 EATON ELECTRIC Contact element, 1N/O, front mount, 6. contact, spring clamp connec..
M22-CK10
216384
Y7-216384
EATON - MOELLER
20 Pcs.
Automation > Auxiliary contact block
Auxiliary Control and Signalling Elements
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The M22-CK10 216384 Y7-216384 EATON ELECTRIC Contact element, 1N/O, front mount, 6. contact, spring clamp connec.. is a switching module engineered for integration into control and signaling units. Engineers typically employ contact elements inside pushbuttons and selector switches to open or close low-current control circuits in machinery control panels. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of contacts as change-over contact (EF008257): 0
- Number of contacts as normally open contact (EF008256): 1
- Number of contacts as normally closed contact (EF008255): 0
- Number of fault-signal switches (EF007613): 0
- Rated operation current Ie at AC-15, 230 V (EF001385): 6 A
- Type of electric connection (EF003961): Spring clamp connection
- Model (EF000010): Top mounting and integrable
- Mounting method (EF000003): Front fastening
More info
▲General specifications
CSA Std. C22.2 No. 94-91
CSA Std. C22.2 No. 14-05
EN 60947-5
IEC 60947-5
CE
CSA File No.: 012528
CSA-C22.2 No. 94-91
IEC 60947-5-1
UL
UL Category Control No.: NKCR
CSA Class No.: 3211-03
UL/CSA
UL File No.: E29184
CSA
IEC
IEC/EN 60947-5
CSA-C22.2 No. 14-05
Features & Functions
General
700,000 Operations (at 230 V, AC-15, 3 A)
1,200,000 Operations (at 12 V, DC-13, 2.8 A)
1,000,000 Operations (at 230 V, AC-15, 1 A)
Can be used with NZM2 size circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker.
Can be used with NZM4 circuit-breaker: up to two standard auxiliary contacts can be clipped into the circuit-breaker.
Can be used with NZM1, 2, 3 circuit-breaker: a trip-indicating auxiliary contact can be clipped into the circuit-breaker.
Can be used with NZM3, 4 circuit-breaker: up to three standard auxiliary contacts can be clipped into the circuit-breaker.
Ambient conditions, mechanical
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
2 x (0,5 - 0,75) mm²
Electrical rating
Short-circuit rating
Max. 10 A gG/gL, Fuse, Auxiliary contacts
Communication
Single contact
Cage Clamp
Actuator
Contacts
1 failure per 10,000,000 switching operations (Statistically determined, at 24 V DC/5 mA)