M22-K10 216376 Y7-216376 EATON ELECTRIC Contact element, 1N/O, front mount, 6. contact, screw connection
M22-K10
M22-K10
Y7-216376
EATON - MOELLER
1 unit
Automation > Auxiliary contact block
Auxiliary Control and Signalling Elements
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller Contact element, 1N/O, front mount, 6. contact, screw connection provides a reliable switching stage for command and signaling devices like pushbuttons and selector switches on industrial control desks. These individual contact blocks snap securely into mounting adapters to complete control circuit logic paths.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of contacts as change-over contact: 0
- Number of contacts as normally open contact: 1
- Number of contacts as normally closed contact: 0
- Number of fault-signal switches: 0
- Rated operation current Ie at AC-15, 230 V: 6 A
- Type of electric connection: Screw connection
- Model: Top mounting and integrable
- Mounting method: Front fastening
More info
▲Delivery program
PN1(-4), 2(-4), 3(-4)
N(S)1(-4), 2(-4), 3(-4), 4(-4)
Can be used with NZM1, 2, 3 circuit-breaker: a trip-indicating auxiliary contact can be clipped into the circuit-breaker.
Can be used with NZM4 circuit-breaker: up to two standard auxiliary contacts can be clipped into the circuit-breaker.
Any combinations of the auxiliary contact types are possible.
Not in combination with switch-disconnector PN…
Marking on switch: HIA
Labeling in FI-Block: HIAFI.
If the trip-indicating auxiliary switch in the fault current block is used, the NC contacts operates as a N/O contact and the NC contact operates as an N/O contact.
Can be used with NZM1 circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker.
Can be used with NZM2 size circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker.
Can be used with NZM3, 4 circuit-breaker: up to three standard auxiliary contacts can be clipped into the circuit-breaker.
Any combinations of the auxiliary contact types are possible.
Marking on switch: HIN.
On combination with remote operator NZM-XR... the right mounting location of standard auxiliary contact HIN can be fitted only with individual contacts.
For Std. pack:
M22‐(C)K… : Std. pack = 20 off
The following can be clipped into the switches:
- NZM1: a standard auxiliary contact
- NZM2: up to two M22-(C)K… standard auxiliary contacts
- NZM3: up to three M22-(C)K… standard auxiliary contacts
- NZM4: up to three M22-(C)K… standard auxiliary contacts
Any combinations of the auxiliary contact types are possible.
Marking on switch: HIN
In combination with remote operator NZM‐XR… only single contacts can be fitted to some installation locations of the standard auxiliary contact.
NZM2: Only single contact can be fitted in left installation location of standard auxiliary contact.
NZM3: Only single contact can be fitted in installation locations of standard auxiliary contact.
NZM4: Only single contact can be fitted in right installation location of standard auxiliary contact.
Technical data
Damp heat, cyclic, to IEC 60068-2-30
| M22-(C)K10(01) | M22-CK11(02)(20) | XHIV | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| bei AC = 50/60 Hz | |||||||||||||
| Bemessungsbetriebsstrom | |||||||||||||
| AC-15 | 115 V | Ie | A | 4 | 4 | 4 | |||||||
| 230 V | Ie | A | 4 | 4 | 4 | ||||||||
| 400 V | Ie | A | 2 | - | 2 | ||||||||
| 500 V | Ie | A | 1 | - | 1 | ||||||||
| DC-13 | 24 V | Ie | A | 3 | 3 | 3 | |||||||
| 42 V | Ie | A | 1.7 | 1 | 1.5 | ||||||||
| 60 V | Ie | A | 1.2 | 0.8 | 0.8 | ||||||||
| 110 V | Ie | A | 0.6 | 0.5 | 0.5 | ||||||||
| 220 V | Ie | A | 0.3 | 0.2 | 0.2 | ||||||||
Early-make time of the HIV compared to the main contacts during with make and break switching.
(switch times with manual operation):
NZM1, PN1, N(S)1: ca. 20 ms
NZM2, PN2, N(S)2: ca. 20 ms
NZM3, PN3, N(S)3: ca. 20 ms
NZM4, N(S)4: approx. 90 ms, the HIV switch earlyOffswitchingnotforward.
2 x (0,75 - 2,5) mm2
1 A - 250 V DC A