K3X185/4 067731 Y7-67731 EATON ELECTRIC Connection terminal, 800A, 4p, flat/round
K3X185/4
067731
Y7-67731
EATON - MOELLER
1 Pcs.
Connection terminal, 800A, 4p, flat/round
Terminal Connection, 800A, 4P, Flat/Round
Eaton xEffect K-Type Terminal Enclosures Switch- & Controlgear Enclosure. Connection terminal, 800A, 4p, flat/round
K connecting terminals, for AL and CU, one side round and the other side flat, rated operational current Ie=800 A, number pole=4, terminal capacities: Copper round cable stranded, sectoral stranded, round cable solid, sectoral solid and aluminium round conductor solid, sectoral solid=2x120-240 or 3x50-185 or aluminum sectoral solid=2x150-185 or 3x95-150 mm². Other side: copper band 2x(11x21x1) or Cu bar=50x20 mm, notes: Conversion kits for strip terminal in cable connection available separately, terminal covers available separately
Automation > Rail terminal bar
Connection Accessories for Enclosures
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller four-pole connection terminal provides high-capacity power distribution capability for demanding industrial switchboards and large electrical feeds.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of poles: 4
- Nominal current: 800 A
- Connection type: Screwing
- Mounting method: Screw
- Number of inputs: 2
- Number of outputs: 3
- Suitable for solid conductors: No
- Suitable for stranded conductors: Yes
- Suitable for fine strand conductors: No
- Suitable for extra fine-strand conductors: No
- Conductor cross section, input: 50 mm²
- Conductor cross section, output: 50 mm²
- Conductor cross section, input AWG: 1
- Conductor cross section, output AWG: 0
- Contact safe: Yes
- Height: 140 mm
More info
▲General specifications
Product Name
Eaton xEffect K-Type Terminal Enclosures Switch- & Controlgear Enclosure
Catalog Number
067731
Model Code
K3X185/4
EAN
4015080677314
Product Length/Depth
125 mm
Product Height
140 mm
Product Width
294 mm
Product Weight
10.826 kg
Compliances
RoHS conform
Delivery programme
Type
Accessory/spare part type
Terminations
Terminals, 160 – 1000 A
Terminals, 160 – 1000 A
Nominal current
800 A
Number of poles
Four-pole
Technical data - electrical
Rated insulation voltage (Ui)
1000 VAC
Rated operation current (Ie)
800 A
Technical data - mechanical
Mounting method
Screw
Number of connections (10 mm squared)
0
Number of connections (16 mm squared)
0
Number of connections (25 mm squared)
0
Number of connections (250 kcmil)
0
Number of connections (Less Than 6 mm squared)
0
Number of connections (Less Than AWG 6)
0
Number of connections (Greater Than 25 mm squared)
8
Number of connections (Greater Than 250 kcmil)
0
Number of connections (AWG 2)
0
Number of connections (AWG 4)
0
Number of connections (AWG 4/0)
0
Number of connections (AWG 6)
0
Number of connections (total)
8
Number of inputs
2
Number of outputs
3
Terminal capacity (aluminum cable)
95 mm² - 150 mm² (3x)
150 mm² - 185 mm² (2x)
150 mm² - 185 mm² (2x)
Terminal capacity (conductor)
50 mm x 20 mm
Terminal capacity (copper band)
2 segments of 21 mm x 1 mm (11x) for flat strip
Terminal capacity (copper/aluminum cable)
120 mm² - 240 mm² (2x)
50 mm² - 185 mm² (3x)
50 mm² - 185 mm² (3x)
Conductor cross section, input - min
50 mm²
Conductor cross section, input - max
240 mm²
Conductor cross section, input AWG - min
1 mm²
Conductor cross section, input AWG - max
500 mm²
Conductor cross section, output - min
50 mm²
Conductor cross section, output - max
300 mm²
Conductor cross section, output AWG - min
0 mm²
Conductor cross section, output AWG - max
0 mm²
Additional information
Features
Contact safe
Special features
- Conversion kits for strip terminal in cable connection available separately
- Terminal covers available separately
- Including labels for terminal marking U, V, W - X, Y, Z - L1, L2, L3 - T1, T2, T3 - PE, N, PEN, protective earth (ground) symbol
- Relationship of rated operational current →terminal capacity to IEC/EN 60439, VDE 0660 Part 500 or EN 50021
- Outer terminal for round or sectoral conductor, other side for Cu strip
Suitable for
Useful for stranded conductors
Used with
General switchboard accessory
Accessory panel building
Accessory panel building