Connection terminal, 800A, 3p, flat/round Terminal connection, 800A, 3P, flat/round Eaton xEffect K-Type Terminal Enclosures Switch- & Controlgear Enclosure. Connection terminal, 800A, 3p, flat/round K connecting terminals, for AL and CU, one side round and the other side flat, rated operational current Ie=800 A, number pole=3, terminal capacities: Copper round cable stranded, sectoral stranded, round cable solid, sectoral solid and aluminium round conductor solid, sectoral solid=2x120-240 or 3x50-185 or aluminum sectoral solid=2x150-185 or 3x95-150 mm². Other side: copper band 2x(11x21x1) or Cu bar=50x20 mm, notes: Conversion kits for strip terminal in cable connection available separately, terminal covers available separately

Automation > Rail terminal bar
Connection Accessories for Enclosures

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

An Eaton Moeller three-pole connection terminal delivers high-amperage power distribution performance for heavy industrial electrical systems.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Number of poles: 3
  • Nominal current: 800 A
  • Connection type: Screwing
  • Mounting method: Screw
  • Number of inputs: 2
  • Number of outputs: 3
  • Suitable for solid conductors: No
  • Suitable for stranded conductors: Yes
  • Suitable for fine strand conductors: No
  • Suitable for extra fine-strand conductors: No
  • Conductor cross section, input: 50 mm²
  • Conductor cross section, output: 50 mm²
  • Conductor cross section, input AWG: 1
  • Conductor cross section, output AWG: 0
  • Contact safe: Yes
  • Height: 140 mm

More info

▲

General specifications

Product Name
Eaton xEffect K-Type Terminal Enclosures Switch- & Controlgear Enclosure
Catalog Number
065358
Model Code
K3X185/3
EAN
4015080653585
Product Length/Depth
125 mm
Product Height
140 mm
Product Width
222 mm
Product Weight
8.294 kg
Compliances
RoHS conform

Delivery programme

Type
Accessory/spare part type
Terminals, 160 – 1000 A
Terminations
Nominal current
800 A
Number of poles
Three-pole

Technical data - electrical

Rated insulation voltage (Ui)
1000 VAC
Rated operation current (Ie)
800 A

Technical data - mechanical

Mounting method
Screw
Number of connections (10 mm squared)
0
Number of connections (16 mm squared)
0
Number of connections (25 mm squared)
0
Number of connections (250 kcmil)
0
Number of connections (Less Than 6 mm squared)
0
Number of connections (Less Than AWG 6)
0
Number of connections (Greater Than 25 mm squared)
6
Number of connections (Greater Than 250 kcmil)
0
Number of connections (AWG 2)
0
Number of connections (AWG 4)
0
Number of connections (AWG 4/0)
0
Number of connections (AWG 6)
0
Number of connections (total)
6
Number of inputs
2
Number of outputs
3
Terminal capacity (aluminum cable)
95 mm² - 150 mm² (3x)
150 mm² - 185 mm² (2x)
Terminal capacity (conductor)
50 mm x 20 mm
Terminal capacity (copper band)
2 segments of 21 mm x 1 mm (11x) for flat strip
Terminal capacity (copper/aluminum cable)
50 mm² - 185 mm² (3x)
120 mm² - 240 mm² (2x)
Conductor cross section, input - min
50 mm²
Conductor cross section, input - max
240 mm²
Conductor cross section, input AWG - min
1 mm²
Conductor cross section, input AWG - max
500 mm²
Conductor cross section, output - min
50 mm²
Conductor cross section, output - max
300 mm²
Conductor cross section, output AWG - min
0 mm²
Conductor cross section, output AWG - max
0 mm²

Additional information

Features
Contact safe
Special features
  • Conversion kits for strip terminal in cable connection available separately
  • Terminal covers available separately
  • Including labels for terminal marking U, V, W - X, Y, Z - L1, L2, L3 - T1, T2, T3 - PE, N, PEN, protective earth (ground) symbol
  • Relationship of rated operational current →terminal capacity to IEC/EN 60439, VDE 0660 Part 500 or EN 50021
  • Outer terminal for round or sectoral conductor, other side for Cu strip
Suitable for
Useful for stranded conductors
Used with
Accessory panel building
General switchboard accessory

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.