EATON - MOELLER K95/1N/BR K95/1N/BR 012336 Y7-12336 EATON ELECTRIC Connection terminal, 160A, 1p, round/round View larger
Images are for illustrative purposes only. Please refer to data sheet for details

K95/1N/BR 012336 Y7-12336 EATON ELECTRIC Connection terminal, 160A, 1p, round/round

K95/1N/BR

012336

Y7-12336

EATON - MOELLER

1 Pcs.

Connection terminal, 160A, 1p, round/round Terminal connection, 160A, 1P, round/round Eaton xEffect K-Type Terminal Enclosures Switch- & Controlgear Enclosure. Connection terminal, 160A, 1p, round/round K connecting terminals, for AL and CU, one side round and the other side flat, rated operational current Ie=160 A, number pole=1, terminal capacities:Cu, round cable stranded, sectoral stranded, round cable solid, sectoral solid, al, round cable solid, sectoral solid =1x16-95 or Al, sectoral solid=1x35-70 other side: Copper band or Cu bar=mm, notes: Conversion kits for strip terminal in cable connection available separately, terminal covers available separately

Automation > Rail terminal bar
Connection Accessories for Enclosures

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Eaton Moeller K95/1N/BR 012336 Y7-12336 connection terminal, 160A, 1p, round/round establishes secure single-pole connections for power distribution applications. High-capacity terminals ensure dependable electrical conductivity within industrial switchgear.

Pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • Number of poles (EF001391): 1
  • Nominal current (EF000001): 160 A
  • Connection type (EF000124): Screwing
  • Mounting method (EF000003): Screw
  • Number of inputs (EF000318): 1
  • Number of outputs (EF000319): 1
  • Suitable for solid conductors (EF007816): No
  • Suitable for stranded conductors (EF007818): Yes
  • Suitable for fine strand conductors (EF007804): Yes
  • Suitable for extra fine-strand conductors (EF016328): No
  • Conductor cross section, input (EF016330): 10 mm²
  • Conductor cross section, output (EF016331): 10 mm²
  • Conductor cross section, input AWG (EF016332): 8
  • Conductor cross section, output AWG (EF016333): 8
  • Contact safe (EF004521): Yes
  • Height (EF000040): 115 mm

More info

▲

General specifications

Product Name
Eaton xEffect K-Type Terminal Enclosures Switch- & Controlgear Enclosure
Catalog Number
012336
Model Code
K95/1N/BR
EAN
4015080123361
Product Length/Depth
100 mm
Product Height
115 mm
Product Width
37 mm
Product Weight
0.563 kg
Compliances
RoHS conform

Delivery programme

Type
Accessory/spare part type
Terminals, 160 – 1000 A
Terminations
Nominal current
160 A
Number of poles
Single-pole

Technical data - electrical

Rated insulation voltage (Ui)
1000 VAC
Rated operation current (Ie)
160 A

Technical data - mechanical

Mounting method
Screw
Number of connections (10 mm squared)
0
Number of connections (16 mm squared)
0
Number of connections (25 mm squared)
0
Number of connections (250 kcmil)
0
Number of connections (Less Than 6 mm squared)
0
Number of connections (Less Than AWG 6)
0
Number of connections (Greater Than 25 mm squared)
2
Number of connections (Greater Than 250 kcmil)
0
Number of connections (AWG 2)
0
Number of connections (AWG 4)
0
Number of connections (AWG 4/0)
0
Number of connections (AWG 6)
0
Number of connections (total)
2
Number of inputs
1
Number of outputs
1
Terminal capacity (aluminum cable)
35 mm² - 70 mm² (1x)
Terminal capacity (copper/aluminum cable)
16 mm² - 95 mm² (1x)
Conductor cross section, input - min
10 mm²
Conductor cross section, input - max
95 mm²
Conductor cross section, input AWG - min
8 mm²
Conductor cross section, input AWG - max
3 mm²
Conductor cross section, output - min
10 mm²
Conductor cross section, output - max
95 mm²
Conductor cross section, output AWG - min
8 mm²
Conductor cross section, output AWG - max
3 mm²

Additional information

Features
Contact safe
Special features
  • Conversion kits for strip terminal in cable connection available separately
  • Terminal covers available separately
  • Including labels for terminal marking U, V, W - X, Y, Z - L1, L2, L3 - T1, T2, T3 - PE, N, PEN, protective earth (ground) symbol
  • Relationship of rated operational current →terminal capacity to IEC/EN 60439, VDE 0660 Part 500 or EN 50021
  • Outer terminal for round or sectoral conductor, other side for Cu strip
Suitable for
Fine strand conductors
Useful for stranded conductors
Used with
Accessory panel building
General switchboard accessory

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.