EATON - MOELLER NZM-XSWD-704 NZM-XSWD-704 135530 Y7-135530 EATON ELECTRIC Connection, SmartWireDarwin, for NZM View larger
Images are for illustrative purposes only. Please refer to data sheet for details

NZM-XSWD-704 135530 Y7-135530 EATON ELECTRIC Connection, SmartWireDarwin, for NZM

NZM-XSWD-704

135530

Y7-135530

EATON - MOELLER

1 Pcs.

Connection, SmartWireDarwin, for NZM NZM-XSWD-704 Eaton Moeller series NZM - Molded Case Circuit Breaker. Connection, SmartWire-DT, for NZM Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: the module implements the data connection between the NZM2/3/4 with electronic release and the SmartWire-DT. The switch can also be switched remote using a motor drive. Retentive memory for energy data (kWh). energy data is transmitted through digital input (S 0) from an external energy measuring module NZN...-XMC-SO. 2 digital inputs for the switch status. 2 transistor outputs for remote switching . Status data: NZM: ON/OFF/TRIPPED, load warnings, reason for last trip, actual current value, switch type actual settings of the rotary coding switches. A connection cable for the circuit-breaker and two NZM auxiliary contacts (1xNO, 1xNC) are included as standard.

Automation > Fieldbus, decentr. periphery - communication module
Circuit Breakers NZM Accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

An Eaton Moeller SmartWire-Darwin connection unit (model NZM-XSWD-704) links circuit breakers directly into streamlined automation architectures without traditional control wiring. Connection hardware of this kind reduces installation time and minimizes wiring errors in complex electrical switchboards. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Supply voltage AC 50 Hz (EF007532): 0 V
  • Supply voltage AC 60 Hz (EF007533): 0 V
  • Supply voltage DC (EF007534): 24 V
  • Voltage type (supply voltage) (EF002991): DC
  • Supporting protocol for EtherCAT (EF017564): No
  • Supporting protocol for TCP/IP (EF003050): No
  • Supporting protocol for PROFIBUS (EF003052): No
  • Supporting protocol for CAN (EF003053): No
  • Supporting protocol for INTERBUS (EF003054): No
  • Supporting protocol for ASI (EF003051): No
  • Supporting protocol for KNX (EF003055): No
  • Supporting protocol for Modbus (EF003057): No
  • Supporting protocol for Data-Highway (EF003058): No
  • Supporting protocol for DeviceNet (EF003059): No
  • Supporting protocol for SUCONET (EF003060): No
  • Supporting protocol for LON (EF003017): No

More info

General specifications

Product Name
Eaton Moeller series NZM electronic accessory
Catalog Number
135530
Model Code
NZM-XSWD-704
EAN
4015081323166
Product Length/Depth
90 mm
Product Height
102 mm
Product Width
35 mm
Product Weight
0.18 kg
Compliances
IEC
RoHS conform
Certifications
UL CSA08 (request filed)
IEC/EN 61131-2
EN 50178

Product specifications

Used with
SmartWire-DT interface for NZM circuit breakers
Special features
Type
Accessory
Features
Fieldbus connection over separate bus coupler possible
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Fitted with:
Potential separation
Frame
NZM2/3/4
Pollution degree
2 (EMC)
Burst impulse
2 kV
1 kV
Connection to SmartWire-DT
Plug, 8-pole connection
Connection to SmartWire-DT
Green LED (status SmartWire-DT)
Automatic setting the baud rate
SmartWire-DT slave (station type)
Connection plug: external device plug SWD4-8SF2-5
Isolation
Outputs to SmartWire-DT (potential isolation)
Inputs for SmartWire-DT (potential isolation)
Accessory/spare part type
Diagnostics and communication
Category (EN 954-1)
B
Explosion safety category for dust
None
Explosion safety category for gas
None
Mounting method
Top-hat rail IEC/EN 60715, 35 mm
Wall mounting/direct mounting
Rail mounting possible
Voltage type
DC
Mounting position
Vertical
Overvoltage category
II
Dimensions
35 mm x 90 mm x 101 mm
Safety performance level (EN ISO 13849-1)
None
SIL (IEC 61508)
None
Terminal connection for I/O sensor
Push in terminals
Vibrations at constant acceleration 1 g (IEC/EN 61131-2:2008)
8.4 Hz - 150 Hz
Vibrations at constant amplitude 3.5 mm (IEC/EN 61131-2:2008)
5 Hz - 8.4 Hz
Voltage range of type 1 digital inputs
Low ≤ 5V DC; High ≥ 15V DC
Ambient operating temperature - max
55 °C
Ambient operating temperature - min
-25 °C
Drop height (IEC/EN 60068-2-31)
50 mm
EMC of electromagnetic fields at 1.4 - 2 GHz (IEC/EN 61131-2:2008)
3 V/m
EMC of electromagnetic fields at 2 - 2.7 GHz (IEC/EN 61131-2:2008)
1 V/m
EMC of electromagnetic fields at 80 - 1000 MHz (IEC/EN 61131-2:2008)
10 V/m
EMC of electrostatic air discharge level 3 (IEC/EN 61131-2:2008)
8 KV
EMC of electrostatic contact discharge level 2 (IEC/EN 61131-2:2008)
4 KV
EMC of radiated RFI level 3 (IEC/EN 61131-2:2008)
10 V
Input current of digital inputs
4 mA
Relative humidity
5 - 95 %
Degree of protection
IP20
Overload proof of digital semi-conductor outputs
Yes, with diagnostics
Terminal capacity (cable)
0.25 mm² - 1.5 mm² with ferrule
Terminal capacity (solid wire)
0.2 mm² - 1.5 mm² (AWG 24 - AWG 16)
Functions
SmartWire-DT module NZM circuit breakers
SmartWire-DT slave (product range)
The module implements the data connection between the NZM2/3/4 with electronic release and SmartWire-DT.
Digital input delay
High to low < 0.2 ms
Low to High typ. < 0.2 ms
Shock resistance
9 impacts (IEC 60068-2-27)
Short-circuit tripping current
Max. 1.2 over 3 ms (digital semi-conductor outputs)
System accessory
No
Number of inputs (digital)
8
Protocol
Other bus systems
Lamp load of digital semi-conductor outputs
3 W
Number of outputs (semiconductor)
4
Packaged free fall height (IEC/EN 60068-2-32)
0.3 m
Messages
Actual current value in A
Load warnings
Actual settings of the rotary coding switches
Reason for last trip
Switch type
Status data NZM: ON/OFF/TRIPPED
Output current of digital semiconductor outputs
Normally 0.5 A at 24 V DC
Supply voltage at AC, 50 Hz - max
0 V
Supply voltage at AC, 50 Hz - min
0 V
Supply voltage at AC, 60 Hz - max
0 V
Supply voltage at AC, 60 Hz - min
0 V
Supply voltage at DC - max
24 V
Supply voltage at DC - min
24 V

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.