View larger
EC4P-221-MRXX1 106394 0004519731 EATON ELECTRIC Compact PLC, 24 V DC, 12DI(of 4AI), 6 DO(R), CAN
EC4P-221-MRXX1
106394
0004519731
EATON - MOELLER
1 Pcs.
Automation > PLC device set
EC4P PLCs
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller EC4P-221-MRXX1 is a compact PLC designed to automate small to mid-sized industrial machinery and process control systems. Programmable logic controllers handle centralized logic, monitoring, and sequencing tasks by processing inputs from various sensors and driving outputs to actuators. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Contains function building blocks: Yes
- Contains basic device: Yes
- Contains module rack: No
- Contains power supply: Yes
- Contains analogue input module: Yes
- Contains analogue output module: No
- Contains digital input module: Yes
- Contains digital output module: Yes
- Contains function module: Yes
- Contains technology module: No
- Contains communication module: Yes
- Contains memory unit: Yes
- Contains simulation module: No
- Contains connection cable: No
- Contains control unit: No
- Contains monitor: No
More info
▲General specifications
CSA-C22.2 No. 0-M
IEC/EN 61000-4-2, Level 3
UL File No.: E135462
CE
UL Category Control No.: NRAQ
UL
CSA
CSA Class No.: 2252-01
UL508
CSA File No.: 012528
Features & Functions
190 received bytes in a block (PRG interface RS232, Master mode)
easyNet/CANopen® on board
Analog input module
Libraries
Digital output module
Function module
Documentation
Memory unit
Power supply
Basic device
Digital input module
Engineering software
Communication module
General
30 m, screened, Analog inputs
25,000 Operations (Fluorescent lamp load 10 x 58 W at 230/240 V AC, uncompensated)
25,000 Operations (Fluorescent lamp load 1 x 58 W at 230/240 V AC, conventional, compensated)
25,000 Operations (Filament bulb load at 1000 W, 230/240 V AC)
25,000 Operations (Fluorescent lamp load 10 x 58 W at 230/240 V AC, with upstream electrical device)
10,000,000 Operations (Relay outputs)
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
20.4 - 28.8 V DC
16 A, Short-circuit-proof cos ϕ = 0.5 to 0.7, characteristic B16 at 900 A, Contacts, Relay outputs
R 300 Light Pilot Duty, UL/CSA Control Circuit Rating Codes DC
Ambient conditions, mechanical
Horizontal
Climatic environmental conditions
Condensation: prevent with appropriate measures
Electro magnetic compatibility
2 kV, Signal cable
2 kV, Supply cable
Class B (EN 55022)
0.5 kV, Supply cables, symmetrical, EASY…DC, power pulses (Surge), EMC
According to IEC/EN 61000-4-5, power pulses (Surge), EMC
Terminal capacities
Power supply
Signal 0: < 8 V DC (I7 - I8, I11 - I12, Digital inputs, 24 V DC)
Signal 1: > 15 V DC (I1 - I6, I9 - I10, Digital inputs, 24 V DC)
Signal 1: > 8 V DC (I7 - I8, I11 - I12, Digital inputs, 24 V DC)
According to EN 61131-2
Communication
RJ45, PRG Interface RS232
RJ45, Ethernet
19.2 kBit/s, PRG interface RS232, Master mode
1.2 kBit/s, PRG interface RS232, Master mode
0.6 kBit/s, PRG interface RS232, Master mode
4.8 kBit/s, PRG interface RS232, Master mode
10 MBit/s, 100 m, Ethernet
250 kBit/s at 60 m, CANopen®
38.4 kBit/s, PRG interface RS232, Master mode
57.6 kBit/s, PRG interface RS232, Master mode
500 kBit/s at 25 m, CANopen®
50 kBit/s at 300 m, CANopen®
2.4 kBit/s, PRG interface RS232, Master mode
10 kBit/s at 1000 m , CANopen®
125 kBit/s at 125 m, CANopen®
20 kBit/s at 700 m, CANopen®
9.6 kBit/s, PRG interface RS232, Master mode
14 segments of 16 kByte Program memory data
4 kByte Input Memory
4 kByte Output Memory
256 kByte Program memory code
8 kByte Retain Memory
Input/Output
± 2, (I7, I8, I11, I12) ± 0.12 V, of actual value, within a single device (Analog Inputs)
± 5 s/day (± 0.5 h⁄year), Real-time clock, normally
0.25 ms typ., Digital inputs 24 DC (I5 - I12), Delay time from 0 to 1
Reference input: I3
Counter inputs: I1, I2
Pulse shape: Square
Number of counter inputs: 1 (I1, I2, I3, I4)
Input for reference switch: I4
Counter frequency: ≤ 40 kHz
Signal offset: 90°
2.2 mA (I11 - I12, at 24 V DC, at signal 1)
140 mA
2.2 mA (I7 - I8, at 24 V DC, at signal 1)
3.3 mA (I9 - I10, at 24 V DC, at signal 1)
3.3 mA (I1 - I6, at 24 V DC, at signal 1)
28/28 VA (DC, at R 300)
12
4 (I7, I8, I11, I12, can also be used as analog inputs)
4 (can also be used as analog inputs)
8 Transistor Outputs
6 (relay outputs)
Square (pulse shape)
2 (I1, I2) at 16 Bit or 1 (I1) at 32 Bit
50 kHz, Counter frequency
16/32 Bit (value range)
200000 Operations at DC-13, 24 V DC, 1 A (500 Ops./h)
0.5 Hz, Inductive load, Relay outputs
10 Hz, Relay outputs
8 A DC, at 24 V DC (UL/CSA)
10 A AC, at 240 V AC (UL/CSA)
1 A DC, at R 300 (UL/CSA)
Safety
Between Analog inputs and Interface/memory card: no
Basic isolation: 600 V AC (Relay outputs)
Safe isolation according to EN 50178: 300 V AC (Relay outputs)
Between Digital inputs 24 V DC and Outputs: yes
Between Relay outputs and Inputs: yes
Between Relay outputs and Power supply: yes
In groups (Relay outputs)
Between Analog inputs and Outputs: yes
300 V AC, Between coil and contact, According to EN 50178