EATON - MOELLER LZME1-A80-I LZME1-A80-I 111814 Y7-111814 EATON ELECTRIC Circuit-breaker, 3 p, 80A View larger
Images are for illustrative purposes only. Please refer to data sheet for details

LZME1-A80-I 111814 Y7-111814 EATON ELECTRIC Circuit-breaker, 3 p, 80A

LZME1-A80-I

LZME1-A80-I

Y7-111814

EATON - MOELLER

1 unit

Circuit-breaker, 3 p, 80A LZME1-A80-I

Automation > Power circuit-breaker for trafo/generator/installation protection
Circuit Breakers LZM

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

An Eaton Moeller circuit-breaker (LZME1-A80-I) provides critical circuit protection by disconnecting power when current levels exceed safe operational thresholds. These units are widely integrated into electrical distribution cabinets to safeguard connected machinery from fault conditions.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Rated permanent current Iu: 80 A
  • Rated voltage: 690 V
  • Rated short-circuit breaking capacity Icu at 400 V, 50 Hz: 18 kA
  • Overload release current setting: 63 A
  • Adjustment range short-term delayed short-circuit release: 0 A
  • Adjustment range undelayed short-circuit release: 480 A
  • Device construction: Built-in device fixed built-in technique
  • Integrated earth fault protection: No
  • Type of electrical connection of main circuit: Frame clamp
  • Suitable for DIN rail (top hat rail) mounting: No
  • DIN rail (top hat rail) mounting optional: Yes
  • Number of auxiliary contacts as normally closed contact: 0
  • Number of auxiliary contacts as normally open contact: 0
  • Number of auxiliary contacts as change-over contact: 0
  • With switched-off indicator: No
  • With integrated under voltage release: No

More info

▲
Circuit-breaker, 3 p, 80A

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Power circuit-breaker for trafo/generator/installation protection (EC000228)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Circuit breaker for power transformer, generator and system protection (ecl@ss10.0.1-27-37-04-09 [AJZ716013])
Rated permanent current Iu
80 A
Rated voltage
690 - 690 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
18 kA
Overload release current setting
63 - 80 A
Adjustment range short-term delayed short-circuit release
0 - 0 A
Adjustment range undelayed short-circuit release
480 - 800 A
Integrated earth fault protection
No
Type of electrical connection of main circuit
Frame clamp
Device construction
Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
Yes
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
With switched-off indicator
No
With under voltage release
No
Number of poles
3
Position of connection for main current circuit
Front side
Type of control element
Rocker lever
Complete device with protection unit
Yes
Motor drive integrated
No
Motor drive optional
No
Degree of protection (IP)
IP20

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.