EATON - MOELLER LZME1-A63-I LZME1-A63-I 111813 Y7-111813 EATON ELECTRIC Circuit-breaker, 3 p, 63A View larger
Images are for illustrative purposes only. Please refer to data sheet for details

LZME1-A63-I 111813 Y7-111813 EATON ELECTRIC Circuit-breaker, 3 p, 63A

LZME1-A63-I

111813

Y7-111813

EATON - MOELLER

1 Pcs.

Circuit-breaker, 3 p, 63A LZME1-A63-I

Automation > Power circuit-breaker for trafo/generator/installation protection
Circuit Breakers LZM

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Protect facility branch circuits and machinery with the Eaton Moeller LZME1-A63-I 111813 Y7-111813 EATON ELECTRIC Circuit-breaker, 3 p, 63A. Standard circuit breakers are foundational components in electrical panels, interrupting fault currents and overloads to prevent system damage.

Pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • Rated permanent current Iu (EF001389): 63 A
  • Rated voltage (EF003977): 690 V
  • Overload release current setting (EF002336): 50 A
  • Adjustment range undelayed short-circuit release (EF007131): 380 A
  • Device construction (EF008240): Built-in device fixed built-in technique
  • Integrated earth fault protection (EF007296): No
  • Type of electrical connection of main circuit (EF006819): Frame clamp
  • Suitable for DIN rail (top hat rail) mounting (EF007250): No
  • DIN rail (top hat rail) mounting optional (EF008904): Yes
  • With switched-off indicator (EF007006): No
  • With integrated under voltage release (EF001390): No
  • Number of poles (EF001391): 3
  • Position of connection for main current circuit (EF006671): Front
  • Type of control element (EF006976): Rocker lever
  • Complete device with protection unit (EF008906): Yes
  • Motor drive integrated (EF006697): No

More info

Circuit-breaker, 3 p, 63A

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Power circuit-breaker for trafo/generator/installation protection (EC000228)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Circuit breaker for power transformer, generator and system protection ([email protected] [AJZ716013])
Rated permanent current Iu
63 A
Rated voltage
690 - 690 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
18 kA
Overload release current setting
50 - 63 A
Adjustment range short-term delayed short-circuit release
0 - 0 A
Adjustment range undelayed short-circuit release
380 - 630 A
Integrated earth fault protection
No
Type of electrical connection of main circuit
Frame clamp
Device construction
Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
Yes
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
With switched-off indicator
No
With under voltage release
No
Number of poles
3
Position of connection for main current circuit
Front side
Type of control element
Rocker lever
Complete device with protection unit
Yes
Motor drive integrated
No
Motor drive optional
No
Degree of protection (IP)
IP20

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.