View larger
LZME1-A100-I 111815 Y7-111815 EATON ELECTRIC Circuit-breaker, 3 p, 100A
LZME1-A100-I
LZME1-A100-I
Y7-111815
EATON - MOELLER
1 unit
Automation > Power circuit-breaker for trafo/generator/installation protection
Circuit Breakers LZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller LZME1-A100-I circuit-breaker functions as an automatic switching device that isolates electrical circuits during overloads or short-circuit conditions, protecting valuable industrial machinery and preventing wiring failures.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated permanent current Iu: 100 A
- Rated voltage: 690 V
- Rated short-circuit breaking capacity Icu at 400 V, 50 Hz: 18 kA
- Overload release current setting: 80 A
- Adjustment range short-term delayed short-circuit release: 0 A
- Adjustment range undelayed short-circuit release: 600 A
- Device construction: Built-in device fixed built-in technique
- Integrated earth fault protection: No
- Type of electrical connection of main circuit: Frame clamp
- Suitable for DIN rail (top hat rail) mounting: No
- DIN rail (top hat rail) mounting optional: Yes
- Number of auxiliary contacts as normally closed contact: 0
- Number of auxiliary contacts as normally open contact: 0
- Number of auxiliary contacts as change-over contact: 0
- With switched-off indicator: No
- With integrated under voltage release: No
More info
▲| Low-voltage industrial components (EG000017) / Power circuit-breaker for trafo/generator/installation prot. (EC000228) | |||
| Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Circuit breaker for power transformer, generator and system protection (ecl@ss8.1-27-37-04-09 [AJZ716010]) | |||
Rated permanent current Iu | A | 100 | |
Rated voltage | V | 690 - 690 | |
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz | kA | 18 | |
Overload release current setting | A | 80 - 100 | |
Adjustment range short-term delayed short-circuit release | A | 0 - 0 | |
Adjustment range undelayed short-circuit release | A | 600 - 1000 | |
Integrated earth fault protection | No | ||
Type of electrical connection of main circuit | Frame clamp | ||
Device construction | Built-in device fixed built-in technique | ||
Suitable for DIN rail (top hat rail) mounting | No | ||
DIN rail (top hat rail) mounting optional | Yes | ||
Number of auxiliary contacts as normally closed contact | 0 | ||
Number of auxiliary contacts as normally open contact | 0 | ||
Number of auxiliary contacts as change-over contact | 0 | ||
Switched-off indicator available | No | ||
With under voltage release | No | ||
Number of poles | 3 | ||
Position of connection for main current circuit | Front side | ||
Type of control element | Rocker lever | ||
Complete device with protection unit | Yes | ||
Motor drive integrated | No | ||
Motor drive optional | No | ||
Degree of protection (IP) | IP20 | ||