View larger
LZMC3-4-A400-I 116470 Y7-116470 EATON ELECTRIC Circuit-breaker, 4 p, 400A
LZMC3-4-A400-I
LZMC3-4-A400-I
Y7-116470
EATON - MOELLER
1 unit
Automation > Power circuit-breaker for trafo/generator/installation protection
Circuit Breakers LZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The LZMC3-4-A400-I 116470 Y7-116470 EATON ELECTRIC Circuit-breaker, 4 p, 400A is an essential protective component used in industrial switchgear to automatically interrupt electrical currents during overloads or short circuits. Panel builders integrate these devices into heavy electrical installations to safeguard wiring infrastructure and connected machinery.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated permanent current Iu: 400 A
- Rated voltage: 690 V
- Rated short-circuit breaking capacity Icu at 400 V, 50 Hz: 36 kA
- Overload release current setting: 320 A
- Adjustment range short-term delayed short-circuit release: 0 A
- Adjustment range undelayed short-circuit release: 2400 A
- Power loss: None W
- Device construction: Built-in device fixed built-in technique
- Integrated earth fault protection: false
- Type of electrical connection of main circuit: Screw connection
- Suitable for DIN rail (top hat rail) mounting: false
- DIN rail (top hat rail) mounting optional: false
- Number of auxiliary contacts as normally closed contact: 0
- Number of auxiliary contacts as normally open contact: 0
- Number of auxiliary contacts as change-over contact: 0
- With switched-off indicator: false
More info
▲General specifications
IEC/EN 60947
IEC
Delivery program
Technical data - electrical
400 A (415 V AC-3, making and breaking capacity)
400 A (660-690 V AC-3, making and breaking capacity)
500 A (415 V AC-1, making and breaking capacity)
500 A (690 V AC -1, making and breaking capacity)
300 V AC (between the auxiliary contacts)
3000 operations at 690 V AC-1
2000 operations at 690 V AC-3
2000 operations at 400 V AC-3
Technical data - mechanical
Fixed
In the area of the HMI devices: IP20 (basic protection type)
IP66 (with door coupling rotary handle)
IP10 (tunnel terminal)
Damp heat, constant, to IEC 60068-2-78
Design verification as per IEC/EN 61439 - technical data
Design verification as per IEC/EN 61439
Additional information
Protection unit