View larger
LZMC2-4-VE250/160-I 111953 Y7-111953 EATON ELECTRIC Circuit-breaker, 4 p, 250A, 160A, in 4th pole
LZMC2-4-VE250/160-I
111953
Y7-111953
EATON - MOELLER
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Circuit Breakers LZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A circuit-breaker, represented by the Eaton Moeller LZMC2-4-VE250/160-I, serves as an essential protective component in industrial power distribution panels. It interrupts overloads and short circuits across multi-phase installations to maintain network stability and protect connected hardware.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Rated permanent current Iu (EF001389): 250 A
- Rated voltage (EF003977): 690 V
- Overload release current setting (EF002336): 125 A
- Adjustment range undelayed short-circuit release (EF007131): 3000 A
- Device construction (EF008240): Built-in device fixed built-in technique
- Integrated earth fault protection (EF007296): No
- Type of electrical connection of main circuit (EF006819): Screw connection
- Suitable for DIN rail (top hat rail) mounting (EF007250): No
- DIN rail (top hat rail) mounting optional (EF008904): Yes
- With switched-off indicator (EF007006): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 4
- Position of connection for main current circuit (EF006671): Front
- Type of control element (EF006976): Rocker lever
- Complete device with protection unit (EF008906): Yes
- Motor drive integrated (EF006697): No
More info
▲| Low-voltage industrial components (EG000017) / Power circuit-breaker for trafo/generator/installation prot. (EC000228) | |||
| Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Circuit breaker for power transformer, generator and system protection ([email protected] [AJZ716010]) | |||
Rated permanent current Iu | A | 250 | |
Rated voltage | V | 690 - 690 | |
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz | kA | 36 | |
Overload release current setting | A | 125 - 250 | |
Adjustment range short-term delayed short-circuit release | A | 250 - 2500 | |
Adjustment range undelayed short-circuit release | A | 3000 - 3000 | |
Integrated earth fault protection | No | ||
Type of electrical connection of main circuit | Screw connection | ||
Device construction | Built-in device fixed built-in technique | ||
Suitable for DIN rail (top hat rail) mounting | No | ||
DIN rail (top hat rail) mounting optional | Yes | ||
Number of auxiliary contacts as normally closed contact | 0 | ||
Number of auxiliary contacts as normally open contact | 0 | ||
Number of auxiliary contacts as change-over contact | 0 | ||
Switched-off indicator available | No | ||
With under voltage release | No | ||
Number of poles | 4 | ||
Position of connection for main current circuit | Front side | ||
Type of control element | Rocker lever | ||
Complete device with protection unit | Yes | ||
Motor drive integrated | No | ||
Motor drive optional | Yes | ||
Degree of protection (IP) | IP20 | ||