Request QuoteProduct Overview
Protecting electrical circuits against overcurrent and short-circuit faults, this Eaton Moeller circuit-breaker manages power distribution in industrial and commercial switchgear installations. It safely breaks fault currents to prevent equipment damage and maintain system reliability.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated permanent current Iu (EF001389): 300 A
- Rated voltage (EF003977): 690 V
- Overload release current setting (EF002336): 240 A
- Adjustment range undelayed short-circuit release (EF007131): 2000 A
- Power loss (EF005387): None W
- Device construction (EF008240): Built-in device fixed built-in technique
- Integrated earth fault protection (EF007296): false
- Type of electrical connection of main circuit (EF006819): Screw connection
- Suitable for DIN rail (top hat rail) mounting (EF007250): false
- DIN rail (top hat rail) mounting optional (EF008904): true
- With switched-off indicator (EF007006): false
- With integrated under voltage release (EF001390): false
- Number of poles (EF001391): 3
- Position of connection for main current circuit (EF006671): Front side
- Type of control element (EF006976): Rocker lever
- Complete device with protection unit (EF008906): true
More info
▲| Low-voltage industrial components (EG000017) / Power circuit-breaker for trafo/generator/installation prot. (EC000228) | |||
| Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Circuit breaker for power transformer, generator and system protection ([email protected] [AJZ716010]) | |||
Rated permanent current Iu | A | 300 | |
Rated voltage | V | 690 - 690 | |
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz | kA | 25 | |
Overload release current setting | A | 240 - 300 | |
Adjustment range short-term delayed short-circuit release | A | 0 - 0 | |
Adjustment range undelayed short-circuit release | A | 2000 - 2500 | |
Integrated earth fault protection | No | ||
Type of electrical connection of main circuit | Screw connection | ||
Device construction | Built-in device fixed built-in technique | ||
Suitable for DIN rail (top hat rail) mounting | No | ||
DIN rail (top hat rail) mounting optional | Yes | ||
Number of auxiliary contacts as normally closed contact | 0 | ||
Number of auxiliary contacts as normally open contact | 0 | ||
Number of auxiliary contacts as change-over contact | 0 | ||
Switched-off indicator available | No | ||
With under voltage release | No | ||
Number of poles | 3 | ||
Position of connection for main current circuit | Front side | ||
Type of control element | Rocker lever | ||
Complete device with protection unit | Yes | ||
Motor drive integrated | No | ||
Motor drive optional | Yes | ||
Degree of protection (IP) | IP20 | ||