View larger
LZMB2-A250-I 111924 Y7-111924 EATON ELECTRIC Circuit-breaker, 3 p, 250A
LZMB2-A250-I
LZMB2-A250-I
Y7-111924
EATON - MOELLER
1 unit
Automation > Power circuit-breaker for trafo/generator/installation protection
Circuit Breakers LZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An LZMB2-A250-I 111924 Y7-111924 EATON ELECTRIC Circuit-breaker is an electro-mechanical protective device engineered to automatically disconnect electrical circuits during overload or short-circuit conditions. Facilities management and panel builders deploy these components within commercial and industrial distribution boards to safeguard wiring infrastructure and connected machinery. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated permanent current Iu: 250 A
- Rated voltage: 440 V
- Rated short-circuit breaking capacity Icu at 400 V, 50 Hz: 25 kA
- Overload release current setting: 200 A
- Adjustment range short-term delayed short-circuit release: 0 A
- Adjustment range undelayed short-circuit release: 1500 A
- Device construction: Built-in device fixed built-in technique
- Integrated earth fault protection: No
- Type of electrical connection of main circuit: Screw connection
- Suitable for DIN rail (top hat rail) mounting: No
- DIN rail (top hat rail) mounting optional: Yes
- Number of auxiliary contacts as normally closed contact: 0
- Number of auxiliary contacts as normally open contact: 0
- Number of auxiliary contacts as change-over contact: 0
- With switched-off indicator: No
- With integrated under voltage release: No
More info
▲General specifications
VDE 0660
IEC
Product specifications
Protection unit
DIN rail (top hat rail) mounting optional
Built-in device fixed built-in technique
Damp heat, constant, to IEC 60068-2-78
500 V AC (between auxiliary contacts and main contacts)
IP20
250 A (660-690 V AC-3, making and breaking capacity)
300 A (415 V AC-1, making and breaking capacity)
250 A (415 V AC-3, making and breaking capacity)
IP40 (with insulating surround)
IP10 (tunnel terminal)
Min. 2 segments of 9 mm x 0.8 mm at box terminal
Min. 2 segements of 16 mm x 0.8 mm at rear-side connection (punched)
Max. 10 segments of 16 mm x 0.8 mm at box terminal
6500 operations at 415 V AC-3
10000 operations at 415 V AC-1
0.75 mm² - 2.5 mm² (1x)
M8 at rear-side screw connection
Max. 20 mm x 5 mm direct at switch rear-side connection
4 mm² - 16 mm² (2x) direct at switch rear-side connection
4 mm² - 16 mm² (1x) at box terminal
4 mm² - 16 mm² (1x) direct at switch rear-side connection
4 mm² - 16 mm² (2x) at box terminal
25 mm² - 70 mm² (2x) at box terminal
25 mm² - 70 mm² (2x) direct at switch rear-side connection
25 mm² - 185 mm² (1x) at box terminal