Power distribution systems utilize a circuit breaker to interrupt electrical current automatically during overload conditions, protecting downstream components. The Eaton Moeller LZMB2-4-ASF200/125-I model delivers robust current protection and isolation for industrial switchgear assemblies.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated permanent current Iu (EF001389): 200 A
- Rated voltage (EF003977): 690 V
- Overload release current setting (EF002336): 160 A
- Adjustment range undelayed short-circuit release (EF007131): 1200 A
- Device construction (EF008240): Built-in device fixed built-in technique
- Integrated earth fault protection (EF007296): No
- Type of electrical connection of main circuit (EF006819): Screw connection
- Suitable for DIN rail (top hat rail) mounting (EF007250): No
- DIN rail (top hat rail) mounting optional (EF008904): Yes
- With switched-off indicator (EF007006): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 4
- Position of connection for main current circuit (EF006671): Front
- Type of control element (EF006976): Rocker lever
- Complete device with protection unit (EF008906): Yes
- Motor drive integrated (EF006697): No
More info
▲| Low-voltage industrial components (EG000017) / Power circuit-breaker for trafo/generator/installation prot. (EC000228) | |||
| Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Circuit breaker for power transformer, generator and system protection ([email protected] [AJZ716010]) | |||
Rated permanent current Iu | A | 200 | |
Rated voltage | V | 690 - 690 | |
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz | kA | 25 | |
Overload release current setting | A | 160 - 200 | |
Adjustment range short-term delayed short-circuit release | A | 0 - 0 | |
Adjustment range undelayed short-circuit release | A | 1200 - 2000 | |
Integrated earth fault protection | No | ||
Type of electrical connection of main circuit | Screw connection | ||
Device construction | Built-in device fixed built-in technique | ||
Suitable for DIN rail (top hat rail) mounting | No | ||
DIN rail (top hat rail) mounting optional | Yes | ||
Number of auxiliary contacts as normally closed contact | 0 | ||
Number of auxiliary contacts as normally open contact | 0 | ||
Number of auxiliary contacts as change-over contact | 0 | ||
Switched-off indicator available | No | ||
With under voltage release | No | ||
Number of poles | 4 | ||
Position of connection for main current circuit | Front side | ||
Type of control element | Rocker lever | ||
Complete device with protection unit | Yes | ||
Motor drive integrated | No | ||
Motor drive optional | Yes | ||