View larger
LZMB1-A80-I 111854 Y7-111854 EATON ELECTRIC Circuit-breaker, 3 p, 80A
LZMB1-A80-I
111854
Y7-111854
EATON - MOELLER
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Circuit Breakers LZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller circuit-breaker, identified as LZMB1-A80-I, functions as a reliable protective switching device designed to safeguard low-voltage circuits from overloads and short circuits. These compact thermal-magnetic breakers are standard components in industrial distribution boards and motor control centers.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Rated permanent current Iu (EF001389): 80 A
- Rated voltage (EF003977): 440 V
- Overload release current setting (EF002336): 63 A
- Adjustment range undelayed short-circuit release (EF007131): 480 A
- Device construction (EF008240): Built-in device fixed built-in technique
- Integrated earth fault protection (EF007296): No
- Type of electrical connection of main circuit (EF006819): Frame clamp
- Suitable for DIN rail (top hat rail) mounting (EF007250): No
- DIN rail (top hat rail) mounting optional (EF008904): Yes
- With switched-off indicator (EF007006): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Position of connection for main current circuit (EF006671): Front
- Type of control element (EF006976): Rocker lever
- Complete device with protection unit (EF008906): Yes
- Motor drive integrated (EF006697): No
More info
▲General specifications
IEC/EN 60947
VDE 0660
Delivery program
Technical data - electrical
160 A (380/400 V AC-1, making and breaking capacity)
80 A (415 V AC-3, making and breaking capacity)
80 A (660-690 V AC-3, making and breaking capacity)
500 V AC (between auxiliary contacts and main contacts)
7500 operations at 415 V AC-3
7500 operations at 400 V AC-1
Technical data - mechanical
Built-in device fixed built-in technique
Fixed
IP20
IP66 (with door coupling rotary handle)
IP00 (terminations, phase isolator and band terminal)
0.75 mm² - 1.5 mm² (2x)
Max. 16 mm x 5 mm direct at switch rear-side connection
Min. 12 mm x 5 mm direct at switch rear-side connection
10 mm² - 16 mm² (1x) at box terminal
6 mm² - 16 mm² (2x) at box terminal
16 mm² - 95 mm² (1x) at tunnel terminal
6 mm² - 16 mm² (2x) direct at switch rear-side connection
25 mm² - 70 mm² (1x) direct at switch rear-side connection
25 mm² - 70 mm² (1x) at box terminal
25 mm² (2x) at box terminal
25 mm² - 95 mm² (1x) at tunnel terminal
Max. 9 segments of 9 mm x 0.8 mm at box terminal
Damp heat, cyclic, to IEC 60068-2-30