PKNM-4/1N/C/01-MW 235968 EATON ELECTRIC RCD/MCB combination switch, 4A, 100mA, miniature circuit-br. type C ..
PKNM-4/1N/C/01-MW
235968
EATON - MOELLER
1 Pcs.
Automation > Earth leakage circuit breaker
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This Eaton Moeller PKNM-4/1N/C/01-MW RCD/MCB combination switch ensures comprehensive protection by combining thermal-magnetic circuit breaking with residual current monitoring. Electrical installations use devices of this class to protect branch circuits from overloads and ground faults. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated operational current for specified heat dissipation: I n
- Heat dissipation per pole, current-dependent: P vid
- Equipment heat dissipation, current-dependent: P vid
- Static heat dissipation, non-current-dependent: P vs
- Heat dissipation capacity: P diss
- Number of poles (total) (EF008618): 2
- Number of protected poles (EF005548): 1
- Rated current (EF000227): 4 A
- Rated fault current (EF002358): 0.1 A
- Leakage current type (EF002560): AC
- Current limiting class (EF002568): 3
- Surge current capacity (EF002564): 0.25 kA
- Voltage type (EF000187): AC
- Frequency (EF005455): 50 Hz
- Release characteristic (EF000889): C
- Concurrently switching neutral conductor (EF005997): Yes
More info
▲Technical data for design verification | |||
Rated operational current for specified heat dissipation | In | A | 4 |
Heat dissipation per pole, current-dependent | Pvid | W | 0 |
Equipment heat dissipation, current-dependent | Pvid | W | 1.6 |
Static heat dissipation, non-current-dependent | Pvs | W | 0 |
Heat dissipation capacity | Pdiss | W | 0 |
Operating ambient temperature min. | °C | -25 | |
Operating ambient temperature max. | °C | 40 | |
| 0 | |||
IEC/EN 61439 design verification | |||
10.2 Strength of materials and parts | |||
10.2.2 Corrosion resistance | Meets the product standard's requirements. | ||
10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. | ||
10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. | ||
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects | Meets the product standard's requirements. | ||
10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. | ||
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.7 Inscriptions | Meets the product standard's requirements. | ||
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.4 Clearances and creepage distances | Meets the product standard's requirements. | ||
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. | ||
10.8 Connections for external conductors | Is the panel builder's responsibility. | ||
10.9 Insulation properties | |||
10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. | ||
10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. | ||
10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. | ||
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. | ||
10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. | ||
10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. | ||
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| Circuit breakers and fuses (EG000020) / Earth leakage circuit breaker (EC000905) | |||
| Electric engineering, automation, process control engineering / Electrical installation, device / Residual current protection system / MCB/RCCB combination ([email protected] [AFZ810012]) | |||
Number of poles (total) | 2 | ||
Number of protected poles | 1 | ||
Nominal rated voltage | V | 230 | |
Nominal rated current | A | 4 | |
Rated fault current | A | 0.1 | |
Leakage current type | AC | ||
Current limiting class | 3 | ||
Rated short-circuit breaking capacity EN 60898 | kA | 10 | |
Rated short-circuit breaking capacity IEC 60947-2 | kA | 0 | |
Frequency | 50 Hz | ||
Release characteristic | C | ||
Concurrently switching N-neutral | Yes | ||
Over voltage category | 3 | ||
Pollution degree | 2 | ||
Width in number of modular spacings | 2 | ||
Built-in depth | mm | 70 | |
Suitable for flush-mounted installation | No | ||
Degree of protection (IP) | IP20 | ||
Surge current capacity | kA | 0.25 | |
Voltage type | AC | ||
Antinuisance tripping version | No | ||