View larger
NZMH4-ME875-S1 290384 Y7-290384 EATON ELECTRIC Circuit-breaker, 3p, 875A 1000V
NZMH4-ME875-S1
290384
Y7-290384
EATON - MOELLER
1 Pcs.
Automation > Motor protection circuit-breaker
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An NZMH4-ME875-S1 Eaton Moeller circuit-breaker is a heavy-duty protective device engineered to manage high-capacity electrical distribution systems and heavy industrial loads. Facilities use these robust interrupters to safely isolate circuits and protect heavy infrastructure from catastrophic electrical faults. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 438 A
- Adjustment range undelayed short-circuit release (EF007131): 875 A
- With thermal overload protection (EF006233): Yes
- Phase failure sensitive (EF007400): Yes
- Switch off technique (EF007007): Electronic
- Rated operating voltage (EF001435): 1000 V
- Rated operation power at AC-3, 230 V (EF007025): 250 kW
- Rated operation power at AC-3, 400 V (EF001364): 500 kW
- Type of electrical connection of main circuit (EF006819): Screw connection
- Type of control element (EF006976): Rocker lever
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Degree of protection (IP) (EF005474): IP20
- Height (EF000040): 207 mm
More info
▲General specifications
Product specifications
Built-in device fixed built-in technique
10 segments of 50 mm x 1 mm (2x) at 1-hole module plate
10 segments of 80 mm x 1 mm (2x) at rear-side width extension
Min. 10 segments of 50 mm x 1 mm (2x) at rear-side connection (punched)
Max. 10 segments of 50 mm x 1 mm (2x) at rear-side connection (punched)
Max. 10 segments of 32 mm x 1 mm (2x) at flat conductor terminal
Phase failure sensitive
0.75 mm² - 1.5 mm² (2x)
Max. 50 mm x 10 mm (2x) at rear-side 1-hole module plate
Min. 25 mm x 5 mm at rear-side 1-hole module plate
Max. 80 mm x 10 mm (2x) at rear-side width extension
Min. 25 mm x 5 mm direct at switch rear-side connection
50 mm x 10 mm (2x) at rear-side 2-hole module plate
Max. 50 mm x 10 mm (2x) direct at switch rear-side connection
M10 at rear-side screw connection
Min. 60 mm x 10 mm at rear-side width extension
50 mm² (4x) at rear-side 2-hole module plate
35 mm² - 185 mm² (4x) at rear-side 2-hole module plate
50 mm² - 240 mm² (4x) at 4-hole tunnel terminal
70 mm² - 185 mm² (2x) at rear-side 1-hole module plate
240 mm² (2x) at rear-side width extension
70 mm² - 240 mm² (6x) at rear-side width extension