View larger
NZMB1-S80-CNA 281266 Y7-281266 EATON ELECTRIC Circuit-breaker, 3p, 80A
NZMB1-S80-CNA
281266
Y7-281266
EATON - MOELLER
1 Pcs.
Automation > Motor protection circuit-breaker
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller circuit-breaker (NZMB1-S80-CNA) is a molded case protective device used in electrical distribution networks to interrupt fault currents and protect downstream circuits from overcurrent conditions. Such units provide reliable manual switching and automatic fault clearance within commercial and industrial power architectures.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 0 A
- Adjustment range undelayed short-circuit release (EF007131): 640 A
- With thermal overload protection (EF006233): No
- Phase failure sensitive (EF007400): No
- Switch off technique (EF007007): Magnetic
- Rated operating voltage (EF001435): 440 V
- Rated permanent current Iu (EF001389): 80 A
- Rated operation power at AC-3, 230 V (EF007025): 22 kW
- Rated operation power at AC-3, 400 V (EF001364): 45 kW
- Type of control element (EF006976): Rocker lever
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Degree of protection (IP) (EF005474): IP20
- Height (EF000040): 165.5 mm
More info
▲General specifications
UL 489
UL (File No. E31593)
UL listed
UL/CSA
CSA (Class No. 1432-01)
IEC 60947-2
CSA-C22.2 No. 5-09
IEC/EN 60947
Specially designed for North America
CE marking
CSA certified
CSA (File No. 22086)
UL (Category Control Number DKPU2)
Product specifications
- Branch circuits, feeder circuits
- Use in unearthed supply systems at 440 V
Built-in device fixed built-in technique
Damp heat, cyclic, to IEC 60068-2-30
500 V AC (between auxiliary contacts and main contacts)
IP20
125 A (415 V AC-1, making and breaking capacity)
IP66 (with door coupling rotary handle)
IP00 (terminations, phase isolator and strip terminal)
Max. 9 segments of 9 mm x 0.8 mm at box terminal
16 mm² - 18 mm² (2x)
M6 at rear-side screw connection
Max. 16 mm x 5 mm direct at switch rear-side connection
6 mm² - 9 mm² (2x) direct at switch rear-side connection
6 mm² - 12 mm² (1x) at box terminal
6 mm² (1x) at tunnel terminal
4 mm² - 3/0 mm² (1x) at tunnel terminal
4 mm² - 2/0 mm² (1x) direct at switch rear-side connection