View larger
NZMB2-S80-CNA 269246 Y7-269246 EATON ELECTRIC Circuit-breaker, 3p, 80A
NZMB2-S80-CNA
269246
Y7-269246
EATON - MOELLER
1 Pcs.
Automation > Motor protection circuit-breaker
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller NZMB2-S80-CNA circuit-breaker provides magnetic trip protection to safeguard industrial distribution networks and machinery feeds from excessive fault currents. These fixed-mounting devices are standard additions to electrical panels requiring reliable short-circuit isolation.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 0 A
- Adjustment range undelayed short-circuit release (EF007131): 8 A
- With thermal overload protection (EF006233): No
- Phase failure sensitive (EF007400): No
- Switch off technique (EF007007): Magnetic
- Rated operating voltage (EF001435): 440 V
- Rated permanent current Iu (EF001389): 80 A
- Rated operation power at AC-3, 230 V (EF007025): 22 kW
- Rated operation power at AC-3, 400 V (EF001364): 45 kW
- Type of electrical connection of main circuit (EF006819): Screw connection
- Type of control element (EF006976): Rocker lever
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Degree of protection (IP) (EF005474): IP20
More info
▲General specifications
IEC
CSA (Class No. 1432-01)
CSA certified
IEC 60947-2
UL listed
UL (File No. E31593)
UL (Category Control Number DKPU2)
Specially designed for North America
CSA-C22.2 No. 5-09
IEC/EN 60947
CSA (File No. 22086)
CE marking
UL/CSA
Product specifications
- Branch circuits, feeder circuits
- Use in unearthed supply systems at 440 V
Fixed
Damp heat, cyclic, to IEC 60068-2-30
300 V AC (between the auxiliary contacts)
IP20 (basic degree of protection, in the operating controls area)
80 A (660-690 V AC-3, making and breaking capacity)
300 A (415 V AC-1, making and breaking capacity)
IP66 (with door coupling rotary handle)
IP10 (tunnel terminal)
Min. 2 segements of 16 mm x 0.8 mm at rear-side connection (punched)
Min. 2 segments of 9 mm x 0.8 mm at box terminal
Max. 10 segments of 16 mm x 0.8 mm at box terminal
6500 operations at 415 V AC-3
14 mm² - 18 mm² (1x)
M8 at rear-side screw connection
Max. 20 mm x 5 mm direct at switch rear-side connection
6 mm² (1x) at tunnel terminal
6 mm² - 11 mm² (1x) direct at switch rear-side connection
4 mm² - 3/0 mm² (1x) direct at switch rear-side connection
4 mm² - 350 mm² (1x) at box terminal