View larger
NZMB2-AF80-NA 269162 Y7-269162 EATON ELECTRIC Circuit-breaker, 3p, 80A
NZMB2-AF80-NA
269162
Y7-269162
EATON - MOELLER
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Constructed by Eaton Moeller, the NZMB2-AF80-NA 269162 Y7-269162 EATON ELECTRIC Circuit-breaker, 3p, 80A operates as a molded case circuit breaker for commercial machinery and panel protection. Technicians use these devices to safeguard electrical distribution branches from current overloads and short-circuit faults.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated permanent current Iu (EF001389): 80 A
- Rated voltage (EF003977): 440 V
- Overload release current setting (EF002336): 80 A
- Adjustment range undelayed short-circuit release (EF007131): 480 A
- Device construction (EF008240): Built-in device fixed built-in technique
- Integrated earth fault protection (EF007296): No
- Type of electrical connection of main circuit (EF006819): Screw connection
- Suitable for DIN rail (top hat rail) mounting (EF007250): No
- DIN rail (top hat rail) mounting optional (EF008904): Yes
- With switched-off indicator (EF007006): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Position of connection for main current circuit (EF006671): Front
- Type of control element (EF006976): Rocker lever
- Complete device with protection unit (EF008906): Yes
- Motor drive integrated (EF006697): No
More info
▲General specifications
UL/CSA
IEC
CSA (Class No. 1432-01)
CSA-C22.2 No. 5-09
UL (Category Control Number DIVQ)
CE marking
UL 489
CSA certified
IEC 60947-2
IEC/EN 60947
Specially designed for North America
UL (File No. E31593)
UL listed
Product specifications
- Branch circuits, feeder circuits
- Use in unearthed supply systems at 440 V
Protection unit
Fixed
DIN rail (top hat rail) mounting optional
Damp heat, constant, to IEC 60068-2-78
500 V AC (between auxiliary contacts and main contacts)
IP20 (basic degree of protection, in the operating controls area)
300 A (415 V AC-1, making and breaking capacity)
IP66 (with door coupling rotary handle)
IP10 (tunnel terminal)
Min. 2 segements of 16 mm x 0.8 mm at rear-side connection (punched)
Min. 2 segments of 9 mm x 0.8 mm at box terminal
Max. 10 segments of 16 mm x 0.8 mm at rear-side connection (punched)
6500 operations at 415 V AC-3
Current limiting circuit breaker
16 mm² - 18 mm² (2x)
M8 at rear-side screw connection
Min. 16 mm x 5 mm direct at switch rear-side connection
16 mm² (1x) at tunnel terminal
6 mm² - 12 mm² (1x) at box terminal
4 mm² - 350 mm² (1x) at box terminal
4 mm² - 350 mm² (1x) at tunnel terminal