NZMB2-S63-CNA 269245 Y7-269245 EATON ELECTRIC Circuit-breaker, 3p, 63A
NZMB2-S63-CNA
269245
Y7-269245
EATON - MOELLER
1 Pcs.
Automation > Motor protection circuit-breaker
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Manage medium-amperage industrial circuits safely with the Eaton Moeller NZMB2-S63-CNA circuit-breaker. These units are commonly integrated into commercial power distribution panels to interrupt fault currents and prevent damage to electrical supply wiring. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 0 A
- Adjustment range undelayed short-circuit release (EF007131): 8 A
- With thermal overload protection (EF006233): No
- Phase failure sensitive (EF007400): No
- Switch off technique (EF007007): Magnetic
- Rated operating voltage (EF001435): 440 V
- Rated permanent current Iu (EF001389): 63 A
- Rated operation power at AC-3, 230 V (EF007025): 18.5 kW
- Rated operation power at AC-3, 400 V (EF001364): 30 kW
- Type of electrical connection of main circuit (EF006819): Screw connection
- Type of control element (EF006976): Rocker lever
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Degree of protection (IP) (EF005474): IP20
More info
▲General specifications
IEC 60947-2
CE marking
IEC/EN 60947
IEC
UL 489
UL/CSA
CSA (Class No. 1432-01)
Specially designed for North America
UL listed
CSA (File No. 22086)
UL (File No. E31593)
UL (Category Control Number DKPU2)
CSA certified
Product specifications
- Branch circuits, feeder circuits
- Use in unearthed supply systems at 440 V
Fixed
Damp heat, constant, to IEC 60068-2-78
500 V AC (between auxiliary contacts and main contacts)
IP20
300 A (415 V AC-1, making and breaking capacity)
300 A (400 V AC-1, making and breaking capacity)
IP40 (with insulating surround)
IP00 (terminations, phase isolator and strip terminal)
Min. 2 segments of 9 mm x 0.8 mm at box terminal
Max. 10 segments of 16 mm x 0.8 mm at box terminal
Max. 10 segments of 16 mm x 0.8 mm at rear-side connection (punched)
6500 operations at 415 V AC-3
14 mm² - 18 mm² (1x)
M8 at rear-side screw connection
Max. 20 mm x 5 mm direct at switch rear-side connection
6 mm² - 11 mm² (1x) direct at switch rear-side connection
6 mm² - 12 mm² (1x) at box terminal
4 mm² - 350 mm² (1x) at box terminal
4 mm² - 3/0 mm² (1x) direct at switch rear-side connection