NZMN1-S50-CNA 281277 Y7-281277 EATON ELECTRIC Circuit-breaker, 3p, 50A
NZMN1-S50-CNA
281277
Y7-281277
EATON - MOELLER
1 Pcs.
Automation > Motor protection circuit-breaker
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
NZMN1-S50-CNA 281277 Y7-281277 EATON ELECTRIC Circuit-breaker, 3p, 50A from Eaton Moeller is a magnetic circuit breaker used to protect distribution systems and connected loads against sudden fault currents. Equipment of this kind provides reliable manual switching and automatic magnetic interruption in electrical distribution systems.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 0 A
- Adjustment range undelayed short-circuit release (EF007131): 400 A
- With thermal overload protection (EF006233): false
- Phase failure sensitive (EF007400): false
- Switch off technique (EF007007): Magnetic
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): 50 A
- Rated operation power at AC-3, 230 V (EF007025): 15 kW
- Rated operation power at AC-3, 400 V (EF001364): 22 kW
- Power loss (EF005387): None W
- Type of control element (EF006976): Rocker lever
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): false
- With integrated under voltage release (EF001390): false
- Number of poles (EF001391): 3
- Degree of protection (IP) (EF005474): IP20
More info
▲General specifications
CE marking
IEC 60947-2
Specially designed for North America
CSA (File No. 22086)
UL/CSA
CSA certified
UL listed
UL (File No. E31593)
IEC
UL (Category Control Number DKPU2)
CSA-C22.2 No. 5-09
CSA (Class No. 1432-01)
UL 489
Product specifications
- Branch circuits, feeder circuits
- Use in unearthed supply systems at 690 V
Built-in device fixed built-in technique
Damp heat, cyclic, to IEC 60068-2-30
500 V AC (between auxiliary contacts and main contacts)
IP20
160 A (400 V AC-1, making and breaking capacity)
125 A (415 V AC-1, making and breaking capacity)
50 A (690 V AC-1, making and breaking capacity)
IP66 (with door coupling rotary handle)
IP00 (terminations, phase isolator and strip terminal)
Min. 2 segments of 9 mm x 0.8 mm at box terminal
7500 operations at 400 V AC-3
7500 operations at 415 V AC-3
16 mm² - 18 mm² (2x)
Max. 16 mm x 5 mm direct at switch rear-side connection
M8 at rear-side screw connection
6 mm² - 12 mm² (1x) at box terminal
6 mm² - 9 mm² (2x) direct at switch rear-side connection
16 mm² - 95 mm² (1x) at tunnel terminal
25 mm² (2x) at box terminal
25 mm² - 70 mm² (1x) at box terminal
4 mm² - 2/0 mm² (1x) direct at switch rear-side connection