View larger
NZMN2-S50-CNA 269256 Y7-269256 EATON ELECTRIC Circuit-breaker, 3p, 50A
NZMN2-S50-CNA
269256
Y7-269256
EATON - MOELLER
1 Pcs.
Automation > Motor protection circuit-breaker
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller NZMN2-S50-CNA 269256 Y7-269256 EATON ELECTRIC Circuit-breaker, 3p, 50A is a robust circuit protection component deployed in industrial power distribution systems to guard against electrical overloads and short circuits. These devices offer reliable switching capabilities for demanding electrical loads in manufacturing plants.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 0 A
- Adjustment range undelayed short-circuit release (EF007131): 8 A
- With thermal overload protection (EF006233): No
- Phase failure sensitive (EF007400): No
- Switch off technique (EF007007): Magnetic
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): 50 A
- Rated operation power at AC-3, 230 V (EF007025): 15 kW
- Rated operation power at AC-3, 400 V (EF001364): 22 kW
- Type of electrical connection of main circuit (EF006819): Screw connection
- Type of control element (EF006976): Rocker lever
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Degree of protection (IP) (EF005474): IP20
More info
▲General specifications
UL (File No. E31593)
CSA certified
UL 489
CSA (Class No. 1432-01)
UL (Category Control Number DKPU2)
IEC/EN 60947
CSA-C22.2 No. 5-09
IEC 60947-2
UL/CSA
CSA (File No. 22086)
UL listed
CE marking
IEC
Product specifications
- Branch circuits, feeder circuits
- Use in unearthed supply systems at 690 V
Fixed
Damp heat, cyclic, to IEC 60068-2-30
500 V AC (between auxiliary contacts and main contacts)
IP20 (basic degree of protection, in the operating controls area)
300 A (400 V AC-1, making and breaking capacity)
50 A (690 V AC-1, making and breaking capacity)
50 A (660-690 V AC-3, making and breaking capacity)
IP40 (with insulating surround)
IP10 (tunnel terminal)
Max. 10 segments of 16 mm x 0.8 mm at rear-side connection (punched)
Min. 2 segements of 16 mm x 0.8 mm at rear-side connection (punched)
Max. 10 segments of 16 mm x 0.8 mm at box terminal
7500 operations at 690 V AC-1
10000 operations at 400 V AC-1
5000 operations at 690 V AC-3
6500 operations at 400 V AC-3
16 mm² - 18 mm² (2x)
Min. 16 mm x 5 mm direct at switch rear-side connection
M8 at rear-side screw connection
16 mm² (1x) at tunnel terminal
6 mm² - 12 mm² (1x) at box terminal
4 mm² - 350 mm² (1x) at box terminal
4 mm² - 350 mm² (1x) at tunnel terminal