View larger
NS3-400-NA 102687 Y7-102687 EATON ELECTRIC Circuit-breaker 3p 400A
NS3-400-NA
102687
Y7-102687
EATON - MOELLER
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller NS3-400-NA circuit-breaker provides reliable protection against electrical overloads and short circuits in industrial power distribution networks. These three-pole protective devices are commonly employed in commercial switchboards and motor control centers to ensure system safety and prevent catastrophic equipment failure during fault conditions.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated permanent current Iu (EF001389): 400 A
- Rated voltage (EF003977): 690 V
- Overload release current setting (EF002336): 0 A
- Adjustment range undelayed short-circuit release (EF007131): 6600 A
- Device construction (EF008240): Built-in device fixed built-in technique
- Integrated earth fault protection (EF007296): No
- Type of electrical connection of main circuit (EF006819): Screw connection
- Suitable for DIN rail (top hat rail) mounting (EF007250): No
- DIN rail (top hat rail) mounting optional (EF008904): Yes
- With switched-off indicator (EF007006): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Position of connection for main current circuit (EF006671): Front
- Type of control element (EF006976): Rocker lever
- Complete device with protection unit (EF008906): Yes
- Motor drive integrated (EF006697): No
More info
▲General specifications
RoHS conform
UL 489
IEC 60947-2
Specially designed for North America
CSA-C22.2 No. 5-09
UL (Category Control Number WJAZ)
UL (File No. E148671)
UL listed
CSA certified
CSA (File No. 22086)
IEC
CE marking
UL/CSA
CSA (Class No. 4652-06)
Product specifications
Protection unit
Built-in device fixed built-in technique
DIN rail (top hat rail) mounting optional
IP20
IP66 (with door coupling rotary handle)
IP00 (terminations, phase isolator and band terminal)
10 segments of 50 mm x 1 mm (2x) at rear-side width extension
Max. 10 segments of 24 mm x 1 mm + 5 segments of 24 mm x 1 mm
Min. 6 segments of 16 mm x 0.8 mm at rear-side connection (punched)
NA: 10 segments of 50 mm x 1 mm (2x) at rear-side width extension
Min. 6 segments of 16 mm x 0.8 mm at box terminal
Max. 10 segments of 32 mm x 1 mm + 5 segments of 32 mm x 1 mm at rear-side connection (punched)
Max. 8 segments of 24 mm x 1 mm (2x) at box terminal
NA: min. 6 segments of 16 mm x 0.8 mm at rear-side connection (punched)
2000 operations at 690 V AC-3
2000 operations at 400 V AC-3
3000 operations at 415 V AC-1
2000 operations at 415 V AC-3
3000 operations at 690 V AC-1
Min. 20 mm x 5 mm direct at switch rear-side connection
NA: max. 10 mm x 50 mm (2x) at rear-side width extension
NA: max. 30 mm x 10 mm + 30 mm x 5 mm direct at switch rear-side connection
NA: M10 at rear-side screw connection
NA: min. 20 mm x 5 mm direct at switch rear-side connection
Max. 30 mm x 10 mm + 30 mm x 5 mm direct at switch rear-side connection
M10 at rear-side screw connection
300 mm² (2x) at rear-side width extension
16 mm² (1x) direct at switch rear-side connection
16 mm² (2x) at box terminal
NA: 500 AWG/kcmil (2x) at rear-side width extension
NA: 6 AWG (1x) at tunnel terminal
16 mm² (1x) direct at switch rear-side connection
16 mm² (1x) at tunnel terminal
25 mm² - 240 mm² (2x) direct at switch rear-side connection
NA: Max. 500 AWG/kcmil (2x) at 2-hole tunnel terminal
25 mm² - 120 mm² (2x) at box terminal
25 mm² - 240 mm² (1x) direct at switch rear-side connection
35 mm² - 240 mm² (1x) at box terminal
NA: Max. 500 AWG/kcmil (1x) at 2-hole tunnel terminal
NA: 2 - 500 AWG/kcmil (1x) at box terminal
50 mm² - 240 mm² (1x) at 2-hole tunnel terminal
25 mm² - 120 mm² (1x) direct at switch rear-side connection
50 mm² - 240 mm² (2x) at 2-hole tunnel terminal
25 mm² - 120 mm² (2x) direct at switch rear-side connection