View larger
NZMB1-S2-CNA 102907 Y7-102907 EATON ELECTRIC Circuit-breaker, 3p, 2A
NZMB1-S2-CNA
102907
Y7-102907
EATON - MOELLER
1 Pcs.
Automation > Motor protection circuit-breaker
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller NZMB1-S2-CNA circuit-breaker provides precise magnetic fault protection for low-current industrial power distribution lines. Panel builders integrate such devices into electrical enclosures to isolate minor branch circuits and prevent cascading failures during overcurrent events.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 0 A
- Adjustment range undelayed short-circuit release (EF007131): 12 A
- With thermal overload protection (EF006233): false
- Phase failure sensitive (EF007400): false
- Switch off technique (EF007007): Magnetic
- Rated operating voltage (EF001435): 440 V
- Rated permanent current Iu (EF001389): 2 A
- Rated operation power at AC-3, 230 V (EF007025): 0.37 kW
- Rated operation power at AC-3, 400 V (EF001364): 0.75 kW
- Power loss (EF005387): None W
- Type of control element (EF006976): Rocker lever
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): false
- With integrated under voltage release (EF001390): false
- Number of poles (EF001391): 3
- Degree of protection (IP) (EF005474): IP20
More info
▲General specifications
UL (File No. E31593)
UL 489
CSA-C22.2 No. 5-09
CSA certified
Specially designed for North America
CSA (Class No. 1432-01)
UL (Category Control Number DKPU2)
CSA (File No. 22086)
UL listed
Product specifications
Fixed
Damp heat, constant, to IEC 60068-2-78
500 V AC (between auxiliary contacts and main contacts)
IP20 (basic degree of protection, in the operating controls area)
IP40 (with insulating surround)
IP00 (terminations, phase isolator and strip terminal)
Max. 9 segments of 9 mm x 0.8 mm at box terminal
14 mm² - 18 mm² (1x)
M6 at rear-side screw connection
Max. 16 mm x 5 mm direct at switch rear-side connection
6 mm² - 9 mm² (2x) direct at switch rear-side connection
6 mm² - 12 mm² (1x) at box terminal
6 mm² (1x) at tunnel terminal
4 mm² - 2/0 mm² (1x) direct at switch rear-side connection