Engineered for fixed installation within industrial switchgear, the Eaton Moeller NZMN1-S26-CNA circuit breaker provides magnetic short-circuit protection for electrical power networks. Such units are deployed in commercial and manufacturing facilities to safeguard distribution lines against severe fault conditions.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 0 A
- Adjustment range undelayed short-circuit release (EF007131): 208 A
- With thermal overload protection (EF006233): No
- Phase failure sensitive (EF007400): No
- Switch off technique (EF007007): Magnetic
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): 26 A
- Rated operation power at AC-3, 230 V (EF007025): 5.5 kW
- Rated operation power at AC-3, 400 V (EF001364): 11 kW
- Type of control element (EF006976): Rocker lever
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Degree of protection (IP) (EF005474): IP20
- Height (EF000040): 165.5 mm
More info
▲General specifications
UL (File No. E31593)
UL (Category Control Number DKPU2)
CSA certified
Specially designed for North America
CSA-C22.2 No. 5-09
CSA (File No. 22086)
CSA (Class No. 1432-01)
UL 489
UL/CSA
Product specifications
Fixed
Damp heat, constant, to IEC 60068-2-78
500 V AC (between auxiliary contacts and main contacts)
IP20
IP66 (with door coupling rotary handle)
IP00 (terminations, phase isolator and strip terminal)
Min. 2 segments of 9 mm x 0.8 mm at box terminal
7500 operations at 415 V AC-3
7500 operations at 400 V AC-3
14 mm² - 18 mm² (1x)
Max. 16 mm x 5 mm direct at switch rear-side connection
Min. 12 mm x 5 mm direct at switch rear-side connection
6 mm² - 12 mm² (1x) direct at switch rear-side connection
6 mm² (1x) at tunnel terminal
6 mm² - 9 mm² (2x) direct at switch rear-side connection
4 mm² - 3/0 mm² (1x) at tunnel terminal
4 mm² - 2/0 mm² (1x) direct at switch rear-side connection